General Maintenance - Bosch ACS 561 Repair Instructions

A/c service unit
Table of Contents

Advertisement

Introduction

General Maintenance

Wipe off the machine often using a clean cloth
to remove grease and dirt.
Electrical Protection
The machine is equipped with a circuit breaker
on the control panel above the ON/OFF switch.
If the breaker trips, its button will pop out. A
tripped circuit breaker will cause the machine
to lose all power. Press the circuit breaker but-
ton to reset. If the circuit breaker does not reset
or continues to trip, there is a fault in the unit
electrical system. Troubleshoot and repair the
affected component(s).
Check for Leaks
The machine checks internal components for
leaks after the initial setup and every 10 days.
Over time, fittings loosen as the machine is
moved.
The machine also checks for internal leaks each
time a filter is replaced.
1. When prompted, connect both service
hoses to their storage ports.
2. Open both coupler valves.
3. Press F1 to perform the leak test.
To perform a manual leak test:
1. Turn OFF the main power switch, and dis-
connect the power cord from the outlet.
2. Remove panels as necessary to use a
leak detector to probe all connections for
refrigerant leaks. Tighten fittings if a leak is
indicated.
3. Reassemble body panels.
SP00D00517
2018-07-11
Tank Fill
This menu item is used to transfer refrigerant
from a source tank to the ISV.
1. Connect the low-side (blue) hose to the
liquid connector on a full source tank.
2. Position the source tank in such a way that
liquid refrigerant is supplied to the connec-
tion. Open the source tank valve.
3. Select TANK FILL from the Setup Menu.
The machine displays
FILL AMOUNT (KG)
CONNECT LOW SIDE HOSE
TO SOURCE TANK
OK TO CONTINUE ESC TO QUIT
4. Enter the quantity to recover, and press F1.
Add at least 2 kg of refrigerant to ensure
enough is available for charging.
5. The machine automatically stops when the
preset tank fill level is reached. To stop the
tank fill before the preset level is reached,
select F2.
6. Close the valve and remove the hose from
the source tank.
7. Press F1 to return to the Setup Menu.
12
ACS 561 Service Manual
XX.XXX
Robert Bosch GmbH

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents