Fmi Table Sae Standard - Volvo TAD650VE Workshop Manual

Industrial engines
Table of Contents

Advertisement

Malfunctions
FMI table
SAE standard
FMI
Display text
0
"Value too high"
1
"Value too low"
2
"Faulty data"
3
"Electrical fault"
4
"Electrical fault"
5
"Electrical fault"
6
"Electrical fault"
7
"Mechanical fault"
8
"Mechanical or electrical fault" Abnormal frequency
9
"Communication fault"
10
"Mechanical or electrical fault" Abnormally large variations
11
"Unknown fault"
12
"Component fault"
13
"Faulty calibration"
14
"Unknown fault"
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
30
SAE text
Valid data, but above the normal working range
Valid data, but below the normal working range
Intermittent or faulty data
Abnormally high voltage or short circuit to higher voltage
Abnormally low voltage or short circuit to lower voltage
Abnormally low current or open circuit
Abnormally high current or short circuit to battery negative
Faulty response from mechanical system
Abnormal updating rate
Unidentified fault
Faulty unit or component
Calibration values outside the limits
Special instructions
Data valid but above normal operating range - least severe level
Data valid but above normal operating range - moderately severe level
Data valid but above normal operating range - least severe level
Data valid but above normal operating range - moderately severe level
Received network data in error
Reserved for SAE assignment
Reserved for SAE assignment
Reserved for SAE assignment
Reserved for SAE assignment
Reserved for SAE assignment
Reserved for SAE assignment
Reserved for SAE assignment
Reserved for SAE assignment
Reserved for SAE assignment
Reserved for SAE assignment
Reserved for SAE assignment
Condition exist
Group 30: Electrical system

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tad750veTad760veTad734geTad660ve

Table of Contents