gloves. Position the unit a maximum of 50 cm in front of the opening of the pipe to be
cleaned. Insert the spiral into the tube until you feel a counter-pressure and the clog-
ging in the tube is reached. Pull the spiral out of the unit until an arc is formed. Make
sure that the working sheet is not too big. Risk of injury!
Move the switch to the FOR position and press the lever. Figure 4 Position b. If the
spiral has penetrated into the tube so far that there is no longer a bow, turn the lever
back into position a and form a new working arc. Repeat this process until the clog-
ging has solved. In case of stiffness it can help the
Turn the spiral briefly backwards (position REV). The right-hand-left (FOR / REV)
prevents the spiral from being locked.
The tool can be released from the clogging by moving back and forth and clockwise
to the left of the spiral.
As soon as the clogging is released or the pipe is cleaned, pull the spiral back out of
the pipe with the hand. Make sure that the hand lever is in position a. Take care that
no water or dirt gets into the unit. After the work has been completed, switch the
switch of the device to OFF and disconnect the device from the mains.
The nuts on support C can be released to regulate the height and inclination of the
unit by adjusting the position of the nuts.
To insert or remove the spiral A into the device, the switch (B) must be in the OFF
position and the side lever must be upwards - as shown in the figure.