Installation Requirements; Special Conditions Of Use - E2S GNExCP7-PT-S Instruction Manual

Atex/iecex/class div/ul38 call points, for use in flammable gas atmospheres
Hide thumbs Also See for GNExCP7-PT-S:
Table of Contents

Advertisement

2.4 ATEX / IECEx Certification
The GNExCP7PT callpoints comply with the following
standards:
EN60079-0:2018 / IEC60079-0:2017 (Ed 7): Explosive
Atmospheres – Part 0: Equipment. General requirements
EN60079-1:2014 / IEC60079-1:2014 (Ed 7): Explosive
Atmospheres - Part 1: Equipment protection by flameproof
enclosures "d"
EN 60079-31:2014 / IEC 60079-31:2013 (Ed 2): Explosive
Atmospheres - Part 31: Equipment dust ignition protection by
enclosure "t"
All units have a rating label, which carries the following
important information: -
GNExCP7-PT-S (Single Switch)
Model No.:
GNExCP7-PT-D (Dual Switch)
DC Units
Input Voltage:
AC Units 250Vac max (units without series
or end-of-line devices only)
Ex db IIC T5 Gb Ta. -55 to +70°C
Ex db IIC T6 Gb Ta. -55 to +60°C
Ex tb IIIC T90°C Db Ta. -55° to +70°C
DEMKO 19 ATEX 2101X
Certificate No.
IECEx ULD 19.0007X
ATEX Marking
Equipment Group and
Category:
CE Marking
Notified Body No.
The units can be installed in locations with the following
conditions:
Area Classification Gas:
Explosive gas air mixture likely to occur in
Zone 1
normal operation.
Explosive gas atmosphere not likely to
Zone 2
occur in normal operation but may be
present for short periods.
Gas Groupings:
Group IIA
Propane
Group IIB
Ethylene
Group IIC
Hydrogen and Acetylene
Temperature Classification:
T1
450ºC
T2
300ºC
T3
200ºC
T4
135ºC
T5
100ºC
T6
85ºC (only up to Tamb 60°C)
Area Classification Dust:
Explosive dust air mixture likely to occur in
Zone 21
normal operation.
Explosive dust air mixture not likely to
Zone 22
occur in normal operation, and if it does, it
will only exist for a short time.
_______________________________________________________________________________________________________________________________
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH
Document No. D202-00-201-IS_Issue_1
48Vdc Max
II 2G
II 2D
0518
07-05-2019
Dust Groupings:
Group IIIA
Combustible Flyings
Group IIIB
Non-conductive Dust
Group IIIC
Conductive Dust
Maximum Surface Temperature for Dust Applications:
90ºC
135°C
IP66/67 to EN/IEC60529 and IP6X to
IP Rating:
EN/IEC60079-0, EN/IEC60079-31
Equipment Category:
Equipment Protection Level:
Ambient Temperature Range:
-55°C to +70°C

3) Installation Requirements

The unit must only be installed by suitably qualified personnel
in accordance with the latest issues of the relevant standards:
EN60079-14 / IEC60079-14: Explosive atmospheres -
Electrical installations design, selection and erection
EN60079-10-1 / IEC60079-10-1: Explosive atmospheres -
Classification of areas. Explosive gas atmospheres
The installation of the unit must also be in accordance with
any local codes that may apply and should only be carried
out by a competent electrical engineer who has the
necessary training.
The equipment must not be installed with any obstruction to
the flanged flameproof joint any closer than permitted as per
EN/IEC60079-14, table 13.

4) Special Conditions of Use

The stainless steel button is not earthed and may generate
an ignition-capable level of electrostatic charges. It has a max
capacitance of 6.33pF according to EN/IEC60079-0, clause
7.5.
Equipment is permitted to be wall mounted only in vertical
position. The enclosure base is permitted in two mounting
positions, with the double entry lowermost or uppermost.
No repair to the Flamepaths is permitted
Flame Path on Base shown
hatched
sales@e2s.com
www.e2s.com
Sheet 2 of 8
2G / 2D
Gb, Gc, Db, Dc
Tel: +44 (0)208 743 8880
Fax: +44 (0)208 740 4200