Selcall Pre-amble Length Setting

The Selcall pre-amble length can be set between 1 and 10 seconds depending on
how many channels are used in the scan table being used. Allow 500 mS for each
Selcall channel to be scanned plus one second, E.g. to scan 8 Selcall channels:-
500 mS x 8 + 1 sec. = 5 seconds.
Use the Scroll keys to select the Selcall pre-amble length
required (example "5 seconds"):-
When the setting required is selected press the
key