Table of Contents 1 Important information Installation data Safety information Serial number SAM 40 - An excellent choice 2 The heating installation – the heart of the house Supply air module function Maintenance of SAM 40 3 Disturbances in comfort...
T3 18°C Serial number must always be given Certification that the installation is carried out according to instructions in the accompanying installer manual and applicable regulations. Date __________________ Signed _________________________ Chapter 1 | Important information NIBE SAM 40...
This symbol indicates tips on how to facilitate using the product. Serial number The serial number can be found at the bottom left inside the front cover. Serial number Caution You need the product's 14 digit serial number for servicing and support. Chapter 1 | Important information NIBE SAM 40...
SAM 40 - An excellent choice SAM 40 is a supply air module that, together with an exhaust air heat pump from NIBE, gives you a complete solution for mechanical exhaust air and pre-heated supply air. Excellent properties for SAM 40: ■...
45 °C 0 °C Outdoor air Room air Refrigerant Heating medium The temperatures are only examples and may vary between different installations and time of year. Chapter 2 | The heating installation – the heart of the NIBE SAM 40 house...
A fan blows the heated air into those rooms that have supply air inlets. The temperatures are only examples and may vary between different installations and time of year. Chapter 2 | The heating installation – the heart of the NIBE SAM 40 house...
Maintenance of SAM 40 Regular checks Your supply air module requires minimal maintenance after commissioning. On the other hand, it is recommended that you check your installation regularly. If something unusual occurs, messages about the malfunction, in the form of different alarm texts, appear in the heat pump display.
Page 11
The default setting for the reminder is every three months; however, if the power supply to the heat pump is interrupted, the countdown starts again. The filter in SAM 40 is of a type that should not be cleaned, but has to be replaced instead.
Page 12
Venting Vent SAM 40 by opening one vent valve at a time, until water comes out. Then close the valve again. Bleed valves XL33 QM20 XL34 HQ11 Chapter 2 | The heating installation – the heart of the NIBE SAM 40...
Selecting "aid mode” is not the same as correcting the problem that caused the alarm. The status lamp will therefore continue to be red. If the alarm does not reset, contact your installer for suitable remedial ac- tion. Chapter 3 | Disturbances in comfort NIBE SAM 40...
Page 14
You need the product's 14 digit serial number for servicing and support. Chapter 3 | Disturbances in comfort NIBE SAM 40...
If the operational interference is not shown in the display the following tips can be used: Basic actions Start by checking the following items: That the heat pump is running or that the supply cable to SAM 40 is ■ connected. Group and main fuses of the accommodation.
4 Technical data Detailed technical specifications for this product can be found in the in- stallation manual (nibe.eu). Chapter 4 | Technical data NIBE SAM 40...
The air coming via the exhaust air valves in the various rooms of the accom- modation, to the heat pump. Supply air The heated air that is blown from SAM 40 and out into the room. Supply air device Valves, usually in the ceiling, where the heated supply air is blown out.
Tel: +7 831 419 57 06 E-mail: kuzmin@evan.ru www.nibe-evan.ru NIBE AB Sweden, Box 14, Hannabadsvägen 5, SE-285 21 Markaryd Tel: +46 (0)433 73 000 E-mail: info@nibe.se www.nibe.se For countries not mention in this list, please contact Nibe Sweden or check www.nibe.eu for more information.
Page 20
WS name: Anna SAM WS version: a2 (working edition) Publish date: 2018-11-16 09:28 NIBE AB Sweden Hannabadsvägen 5 Box 14 SE-285 21 Markaryd info@nibe.se www.nibe.eu 531372...