Appliance Information; General Information; Technical Data - Bosch Worcester Danesmoor Utility Regular ErP+ 12/18 Installation, Commissioning And Servicing Instruction Manual

Floor standing oil-fired condensing boiler conventional flue & room sealed flue
Table of Contents

Advertisement

Appliance information

3
Appliance information
3.1

General information

Standard package:
A - Floor standing oil fired condensing boiler
B - Literature pack:
• Greenstar Danesmoor Installation, Commissioning and Servicing
instruction manual
• User Instructions
• Fascia information card
• Guarantee registration card
C - BSP plug, one inch (Regular only)
D - ErP label
E - Flue damper
370mm
600mm
A
6
B
C
D
855mm
E
3.2

Technical data

Description
Central heating
Central heat output (max)
Primary water capacity (total)
Maximum static head
Minimum static head
Water side resistance (20°C
difference)
Maximum available pump head
(20°C difference) Utility System
Maximum permissible sealed
system operating pressure in
accordance with WRAS
guidelines
Flue
Exit flue gas mass flow
Pipework connections
Fuel line (compression)
Flow Utility
Flow Utility System
Utility flow and optional vent/air
vent
Return
Condensate (Polypropylene)
PRV outlet - Utility System
Electrical
Electrical power supply voltage ac ..V
Frequency
Thermostats
Boiler flow temperature range
(cut in/cut out)
Control thermostat differential
Boiler high limit thermostat set
point
Boiler manual reset overheat
thermostat set point
Flue manual reset overheat
thermostat set point
General data
Maximum hearth temperature
SEDBUK 2009
SEDBUK 2005
Appliance protection rating
Weight (excluding packaging)
Utility Regular
Weight (excluding packaging)
Utility System
Greenstar Danesmoor Utility
ErP+
and Utility System
Units
12/18 18/25 25/32
kW
18
25
32
litres
20
21
22
metres
30
30
30
metres
1
1
1
mbar
20
30
56
mH
O
5.2
4.3
4.1
2
bar
2.5
2.5
2.5
kg/hr
29
40
51
mm
10
10
10
BSP
1"
1"
1"
mm
22
22
28
BSP
1
1
1
mm
22
22
28
mm
21.5
21.5
21.5
mm
15
15
15
230
230
230
Hz
50
50
50
°C
55/81 55/81 55/81
°C
5
5
5
°C
95
95
95
°C
105
105
105
°C
110
110
110
°C
<100
<100
<100
%
91.1
90.9
90.7
%
93.2
93.0
92.8
IP
20
20
20
kg
104
108
115
kg
112
112
122
ErP+
- 6 720 821 720 (2018/04)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Worcester danesmoor utility regular erp+ 18/25Worcester danesmoor utility regular erp+ 25/32Worcester danesmoor utility system erp+ 18/25Worcester danesmoor utility system erp+ 25/32

Table of Contents