6.8

Initialization Level

6.8.1 Calibration
REMARK:
The calibration is already factory-made and must not run again normally.
In individual cases, however, a recalibration of the device after installation can improve
the measuring accuracy, since the mounting factors (such as angle deviation, parallelism,
etc.) are also taken into account.
 Switch off the device (remove battery)
 While pressing the key the device is turning on again
The sensor calibration is initiated and "CAL 0"is displayed. The sensor now has to be moved slowly in a direc-
tion on the magnetic tape, the process of the calibration is shown by the display "CAL 1 ... CAL 4".
After finishing the calibration the device will start automatically in the operator level.
6.8.2 Load the Default Parameters and simultaneous Calibration
REMARK:
Parameters that have already been changed are overwritten by the default parameters!
Therefore make a note of your individual settings before loading the defaults.
 Switch off the device (remove battery)
 While pressing the key the device is turning on again
All parameters are reset to factory settings. Furthermore the sensor calibration (see  6.8.1) is triggered.
6.9

Operator Level Functions

 Working with the device
6.9.1 Set Actual Value to Reference Value
With this shortcut, the actual value (display value) on the adjustable reference value is set (in absolute mode only
possible when the offset is not enabled). The reference value can be entered with the parameter P09.
Keep key pressed
Keep pressing the key
Keys 1x press at the same time
- 16 -