Parameter List - ELGO Electronic HWD15 Series Operating Manual

Battery powered display unit with rotative encoder (1250 ppr)
Table of Contents

Advertisement

6.7

Parameter List

Table 1: Parameter List
Parameter
Function
P01: A
System configuration:
A = 0: positive counting direction
A = 1: negative counting direction
P02: A
Display mode (only affects the display symbols!):
A = 0: mm mode / display symbol „ mm "
A = 1: Inch mode / display symbol „ Inch "
A = 2: mm mode / display symbol „ m "
A = 3: mm mode / display symbol „ ° "
A = 4: mm mode / no display symbol
P03: A
Decimal place ( 0 ... 4 )  only for mm mode
P05: ABC
Key lock:
A: „Set" key
B: „Incr/Abs" key
C: „*" key
P07: A
Basic resolution (only firmware V1.50 and higher):
A = 0: resolution 0.01mm
A = 1: resolution 0.1mm
P08
Pulse multiplication factor (0.0001 ... 9.9999)
P09:
Reference value (−9999999 ... +9999999 )
P10:
Offset 1 (−9999999 ... +9999999 )
P11:
Offset 2 (−9999999 ... +9999999 )
P12:
Offset 3 (−9999999 ... +9999999 )
P13: A
Offset Configuration (0 ... 3)
A = 0: offset cannot be activated
A = 1: offset 1 can be activated
A = 2: offset 1 & 2 can be activated
A = 3: offset 1 & 2 & 3 can be activated
P90:
(no function)
P99:
Display firmware version
(0= enabled / 1= disabled)
(0= enabled / 1= disabled)
(0= enabled / 1= disabled)
- 15 -
Installation and First Start-Up
Default Setting
Customer Setting
0
0
2
000
0
1.0000
0
0
0
0
3
0
x.xx

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hwd15-000-001Hwd15-001-001

Table of Contents