Communication - ABB RELION 630 Series Product Manual

Generator protection and control
Hide thumbs Also See for RELION 630 Series:
Table of Contents

Advertisement

Generator Protection and Control
REG630
Product version: 1.3
Table 3. Analog input configuration
Analog input configuration
AA
AB
AC
BA
BB
BC
Table 4. Binary input/output options for 4U variants
Binary I/O options
Default
With one optional binary I/O module
With two optional binary I/O modules
1)
Not possible if RTD/mA module is selected.
Table 5. Binary input/output options for 6U variants
Binary I/O options
Default
With one optional binary I/O module
With two optional binary I/O modules
With three optional binary I/O modules
With four optional binary I/O modules
1)
Not possible if RTD/mA module is selected.

17. Communication

The protection relay supports the IEC 61850 substation
automation standard including horizontal GOOSE
communication as well as the well-established DNP3 (TCP/IP)
and IEC 60870-5-103 protocols. All operational information
and controls are available through these protocols.
Disturbance files are accessed using the IEC 61850 or IEC
60870-5-103 protocols. Disturbance files are also available to
any Ethernet based application in the standard COMTRADE
format. The protection relay can send binary signals to other
protection relays (so called horizontal communication) using the
IEC 61850-8-1 GOOSE (Generic Object Oriented Substation
Event) profile. Binary GOOSE messaging can, for example, be
employed for protection and interlocking-based protection
schemes. The protection relay meets the GOOSE performance
requirements for tripping applications in distribution
substations, as defined by the IEC 61850 standard. Further, the
protection relay supports the sending and receiving of analog
ABB
CT (1/5 A)
CT sensitive (0.1/0.5 A)
4
7
8
4
7
8
Binary input configuration
AA
AB
AC
1)
Binary input configuration
AA
AB
AC
AD
1)
AE
VT
1
4
-
3
-
2
1
4
-
3
-
2
values using GOOSE messaging. Analog GOOSE messaging
enables fast transfer of analog measurement values over the
station bus, thus facilitating for example sharing of RTD input
values, such as surrounding temperature values, to other relay
applications. The protection relay interoperates with other IEC
61850 compliant devices, tools and systems and
simultaneously reports events to five different clients on the IEC
61850 station bus. For a system using DNP3 over TCP/IP,
events can be sent to four different masters. For systems using
IEC 60870-5-103, the protection relay can be connected to one
master in a station bus with star-topology.
All communication connectors, except for the front port
connector, are placed on integrated communication modules.
The protection relay is connected to Ethernet-based
communication systems via the RJ-45 connector
(10/100BASE-TX) or the fibre-optic multimode LC connector
(100BASE-FX).
1MRS757583 C
RTD/mA
mA outputs
inputs
-
-
-
8
8
8
BI
BO
14
9
23
18
32
27
BI
BO
14
9
23
18
32
27
41
36
50
45
-
-
-
4
4
4
15