Advertisement

HEAT RECOVERY UNIT
ILOX 129
INSTALLATION, OPERATION AND MAINTENANCE

Advertisement

Table of Contents
loading

Summary of Contents for Iloxair ILOX 129

  • Page 1 HEAT RECOVERY UNIT ILOX 129 INSTALLATION, OPERATION AND MAINTENANCE...
  • Page 2: Table Of Contents

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance CONTENTS OPERATION AND MAINTENANCE (FOR USER) Description, control equipment, electrical data, energy class ..3 ISYteq Touch control panel General, general buttons and symbols ..........4 Home screen, description ..............5 Operation, home screen and sub menus .........
  • Page 3: Description, Control Equipment, Electrical Data, Energy Class

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance DESCRIPTION, ELECTRICAL DATA, CONTROL EQUIPMENT FANS ETHERNET CONNECTION (ACCESSORY) The fans are powered by energy-efficient EC motors. This function can be used to connect the unit to an existing network.
  • Page 4: General, General Buttons And Symbols

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance GENERAL BUTTONS AND SYMBOLS GENERAL The following buttons and symbols are universal and available on The control panel has a touch screen display. Use your finger or the many menu pages.
  • Page 5: Home Screen, Description

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance ISYTEQ TOUCH 3.5 CONTROL PANEL - HOME SCREEN STATUS LINE Heat recovery active Postheater active Defrosting in progress CURRENT SETPOINT, CLOCK SUPPLY AIR TEMPERATURE OPERATING STATUS ALARMS Manual mode No alarm...
  • Page 6: Isyteq Touch Control Panel

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance ISYTEQ TOUCH 3.5 CONTROL PANEL - OPERATION SHORTCUT TO SETTING OF TEMPERATURE SETPOINT SHORTCUT TO SETTING OF DATE AND TIME See page 7 for more information on temperatures. ALARMS SELECT OPERATING STATUS See page 7.
  • Page 7: Operation, Sub Menus

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance ISYTEQ TOUCH CONTROL 3.5 PANEL - OPERATION SELECTING OPERATING STATUS MENU The symbol on the home screen shows the operating status. Press the centre of the fan symbol to change the status.
  • Page 8: Maintenance And Cleaning Of Heat Exchanger And Fans

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance MAINTENANCE AND CLEANING OF HEAT EXCHANGER AND FANS GENERAL CLEANING OF FANS The fans, filters and heat exchanger are very important for the opera- Note that the fans must not be cleaned with water or other fluids; they tion and economy of the unit.
  • Page 9: Filter Alarm, Filter Replacement

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance FILTER ALARM AND FILTER REPLACEMENT FILTER ALARM AND FILTER REPLACEMENT If the filter needs replacing ISYteq Touch 3.5 generates an alarm. The supply air and exhaust air filters should normally be replaced eve- ry six months.
  • Page 10: Thermal Overload Protection, Temperature Alarm, Other Alarms

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance THERMAL OVERLOAD PROTECTION, TEMPERATURE ALARM, OTHER ALARMS RESETTING THE THERMAL OVERLOAD PROTECTION Thermal overload protection reset button The fan motors are equipped with thermal overload protection that is reset manually by temporarily disconnecting the power.
  • Page 11: Unit With A Water Coil, Frost Protection

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance UNIT WITH A WATER COIL, FROST PROTECTION UNIT WITH A WATER COIL The frost monitor is used to prevent frost damage to the water coil when outdoor temperatures are low. The frost protection sensor on the...
  • Page 12: Dimensions, Weight And Connections

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance DIMENSIONS AND CONNECTIONS DIMENSIONS, WEIGHT AND CONNECTIONS bb = 14 = Outdoor air right, supply air left bb = 24 = Outdoor air left, supply air right Weight: 70 kg...
  • Page 13: Wiring And Connection Diagram

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance WIRING AND CONNECTION DIAGRAM WIRING AND CONNECTION DIAGRAM, PRINTED CIRCUIT BOARD RS485 Supply air fan L N PE Extract air fan ISYteq Mini B A GND Door switch +10 V...
  • Page 14: Duct Connection, Duct Insulation

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance DUCT CONNECTION, DUCT INSULATION Note! During installation, the instructions regarding unit installation and duct insulation must be adhered to without deviation. Otherwise, there is a risk of condensation and moisture resulting in major damage.
  • Page 15: Installation Options, Definition Of Ducts

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance INSTALLATION OPTIONS AND DUCT DEFINITIONS INTRODUCTION If the unit is not installed immediately after delivery, it should be stored well-protected under a roof in its original packaging. We recommend that the unit always be lifted by two people. Protective gloves should be worn.
  • Page 16: Location, Condensation Drain, Wall Mounting

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance LOCATION, CONDENSATION DRAIN, WALL MOUNTING LOCATION Install the heat recovery unit in a warm space. This should preferably be warmer than +10 °C. The Ilox 89 should be installed on a wall using a wall bracket, or on the ceiling using a ceiling bracket (accessory).
  • Page 17: Installing A Water Heater

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance INSTALLING A WATER HEATER INSTALLING A WATER HEATER Pipes are not included in Connect the water coil to the heating system in the home; in parallel the delivery from FläkGroup Return line Ø15 mm...
  • Page 18: Installing And Connecting The Isyteq Touch Control Panel

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance CONTROL PANEL ISYteq TOUCH 3.5 - INSTALLATION AND CONNECTION 4. Mount the enclosure directly on the wall or using the screws in a junction box. 1. Open the control panel using a screwdriver.
  • Page 19: Adjustment, Commissioning (For Installer And Service Personnel)

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance ADJUSTMENT, COMMISSIONING (FOR INSTALLER AND SERVICE PERSONNEL) SETTINGS DATE / TIME To enter the “Settings” menu: 1. Press the gear cog button. 1. Set the date and continue by pressing “Confirm”.
  • Page 20: Air Flow Calibration, Logging In, Settings

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance AIR FLOW ADJUSTMENT, LOGGING IN, SETTINGS INTRODUCTION SETTINGS FOR INSTALLER AND SERVICE PERSONNEL Adjustment of air flow and temperature may only be carried out by an installation engineer or service personnel.
  • Page 21: Adjusting The Fan Speed

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance CONTROL PANEL OPERATION, COMMISSIONING ADJUSTMENT There are two ways to enter the adjustment menu. 1. The first is to press the question mark on the start screen. The question mark will not be shown if the menu has been opened pre- viously.
  • Page 22 Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance CONTROL PANEL OPERATION, COMMISSIONING STANDARD Option 2 - Enter the desired value, confirm with . Option 1 Option 2 The speeds for each operating mode can be changed in two ways: After configuring the settings, press “Confirm”...
  • Page 23 Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance CONTROL PANEL OPERATION, COMMISSIONING Here you set the desired supply air temperature (setpoint). Note: To complete the adjustment, click the brown check mark. This value is not to be confused with the desired indoor tempera- ture, which is managed by the domestic heating system.
  • Page 24: Parameter List

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance PARAMETER LIST Note that incorrect parameter settings can cause moisture problems, operational disruption and other types of malfunction. For this reason, the settings must be configured by suitably qualified professionals.
  • Page 25 Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance PARAMETER LIST SETTINGS Parameter Type of value Range Unit Standard value Comment Date / Time – – – Select language – – Swedish Reset filter alarm – – – For resetting alarm in advance...
  • Page 26 Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance PARAMETER LIST Parameter Type of value Range Unit Standard value Comment 6. Air quality – – – – Not applicable to the ILOX unit 7. Alarm management 7.1 Alarm settings...
  • Page 27 Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance PARAMETER LIST Parameter Type of value Range Unit Standard value Comment 7.4 Contact functions DI1 Timer input 1 NO/NC – DI2 Timer input 2 NO/NC – DI3 Rotation monitor NO/NC –...
  • Page 28 Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance PARAMETER LIST Type of val- Standard Parameter Range Unit Comment value 9. Save values Saves adjusted values in control panel, max. 5 values Memory 1 – – – – Memory 2 –...
  • Page 29: Ce Declaration Of Conformity

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance ENCLOSURE II A Declaration of Conformity In accordance with: EU Directive for Machinery, 2006/42/EC EU EMC Directive, 2014/30/EU EU Directive for Energy related Products ErP 2009/125/EC EU RoHS Directive, 2011/65/EU Manufacturer FläktGroup Sweden AB...
  • Page 30: Disposal Of Products And Packaging Materials

    Heat Recovery Unit ILOX 129 - Installation, Operation and Maintenance DISPOSAL OF PRODUCTS AND PACKAGING MATERIALS Separate at source according to local regula- tions. Depending on the product, the following should be removed when disposing of it: - Circuit boards, cables, coils, motors, sen- sors etc.
  • Page 31 ILOX 129 + ISYteq Touch 3.5 PRODUCT INFORMATION IN ACCORDANCE WITH COMMISSION REGULATION (EU) NO. 1254/2014 ANNEX IV AS REFERRED TO IN ARTICLE 3(1B) (a) BranD ILOXAIR OY (b) Model designation ILOX 129 Climate zone Energy class Cold –73.5 (c) Specific energy use (SEC) Average –30.6...
  • Page 32 ILOX 129 + ISYteq Touch 3.5 + CO PRODUCT INFORMATION IN ACCORDANCE WITH COMMISSION REGULATION (EU) NO. 1254/2014 ANNEX IV AS REFERRED TO IN ARTICLE 3(1B) (a) BranD ILOXAIR OY (b) Model designation ILOX 129 Climate zone Energy class Cold –78.6...
  • Page 36 WWW.FLAKTGROUP.SE ILOX 129 9416 FläktGroup is the European market leader for smart and energy efficient Indoor Air and Critical Air solutions to support every application area. We offer our customers innovative technologies, high quality and outstanding performance supported by more than a century of accumulated industry experience.

This manual is also suitable for:

Ilox 89