UNIPOINT OPERATING MANUAL

16 Approvals

Unipoint is performance approved to EN60079-29-1 (measuring function) for use with Signal-
point, Sensepoint (Combustible) and any 4-20 mA device.
Caution: Unipoint is a safe area device. It must not be installed in hazardous areas.
Special Conditions of Use
1. The user/installer shall comply with the following environmental restrictions that apply to the
use of this equipment, as stated in the product manual.
Temperature (Equipment): -10°C to 40°C
Temperature (Standard combustible sensor): -40°C to 80°C
Temperature (High temperature sensor): -55°C to 150°C
Humidity: 10% to 90%
Pressure: 90 kPa to 110 kPa
2. The user/installer shall install these products taking into account any restrictions or special
conditions for safe use that are applicable to the previously certified devices that are used in
their construction.
3. When used, the Sensepoint and the Signalpoint Gas detectors shall be powered from Uni-
point DIN controller.
2306M5001 MAN0638 ISSUE 7 01/2011