Allen-Bradley Kinetix 5700 Series Original Instructions page 3

Dual-axis inverters
Hide thumbs Also See for Kinetix 5700 Series:

Advertisement

Ground Screw Installation
Included with the drive module connector set is a ground screw. Install the ground screw for grounded (wye)
power configurations. Do not install the ground screw when using ungrounded, corner-grounded, or
impedance-grounded power, the Bulletin 8720MC regenerative power supply, or any active converter.
If you have grounded-wye power distribution and 2198-P
IMPORTANT
ground screw. EMC performance can be affected if the ground screw is not installed.
We recommend that you install the ground screw when the drive is removed from the panel and placed on its
side on a solid surface equipped as a grounded static-safe workstation.
ATTENTION: When the ground screw is not installed, the risk of equipment damage exists
because the unit no longer maintains line-to-neutral voltage protection.
To access the ground screw on dual-axis inverters, open the small plastic door on the right side of the module.
Install the Ground Screw
2198-D -ERS
Dual-axis Inverter
(side view)
Ground Screw
ATTENTION: To avoid personal injury, the ground screw access door must be kept closed when
power is applied. If power is applied, and then removed, wait at least 5 minutes for the DC-bus
voltage to dissipate, and verify that no DC-bus voltage exists before accessing the ground screw.
ATTENTION: Risk of equipment damage exists. The drive ground configuration must be
accurately determined. Install the ground screw for grounded power configurations. Do not
install the screw for ungrounded, corner-grounded, and impedance-grounded power, or when an
active converter supplies the DC-bus voltage.
Ground Screw Configurations
Ground Screw
(1)
Ground Configuration
Configuration
Grounded (wye)
Installed
• AC-fed ungrounded
• Corner grounded
Not installed (default setting)
• Impedance grounded
DC-bus from active converter
(1)
Refer to the Kinetix 5700 Servo Drives User Manual, publication 2198-UM002, for example power configurations.
Mount the Dual-axis Inverter
Observe these clearance requirements when mounting the dual-axis inverter:
• Additional clearance is required for cables and wires or the shared-bus connection system connected to the
top of the drive.
• Additional clearance is required if other devices are installed above and/or below the drive and have
clearance requirements of their own.
• Additional clearance left and right of the drive is required when mounted adjacent to noise sensitive
equipment or clean wire ways.
• The recommended minimum cabinet depth is 300 mm (11.81 in.).
Refer to the Kinetix Servo Drives Technical Data, publication KNX-TD003, for Kinetix 5700 drive dimensions.
The Kinetix 5700 drive system must be spaced by aligning the zero-stack tab and cutout. For hole patterns, refer
to the Kinetix 5700 Servo Drives User Manual, publication 2198-UM002.
MOD
NET
Zero-stack Tab and
Cutout Aligned
Mount the Kinetix 5700 servo drives to the cabinet subpanel with M5 (#10-32) steel bolts torqued to 4.0 N•m
(35.4 lb•in), max.
DC-bus power supply, install the
Ground Screw
Access Door
Ground Screw
Install the ground screw for grounded power
configurations. Do not install the ground screw for
ungrounded, corner-grounded, and impedance-grounded
power or grounded systems with active power supplies
(screw not installed is the default setting).
Benefits of Configuration
• UL and EMC compliance
• Reduced electrical noise
• Most stable operation
• Reduced voltage stress on
components and motor bearings
• Helps avoid severe equipment
damage when ground fault occurs
• Reduced leakage current
Shared-bus connection system
is not shown for clarity.
MOD
MOD
NET
NET
Rockwell Automation Publication 2198-PC002D-EN-P - November 2017
Minimum Clearance Requirements
40 mm (1.57 in.) clearance above
drive for airflow and installation.
2198-D -ERS
Dual-axis Inverter
(front view)
Clearance left of the
drive is not required.
Refer to the Kinetix Servo Drives
93 mm
Technical Data, publication KNX-TD003,
(3.7 in.)
for Kinetix 5700 drive dimensions.
IMPORTANT Mount the drive in an upright position as shown. Do not mount the drive on its side.
Connector Data
Use this illustration to identify the dual-axis inverter features and indicators.
Dual-axis Inverters Features and Indicators (2198-D006-ERS inverter is shown)
11
11
12
MOD–
13
NET–
5700
14
15
10
2
16
9
1
17
I/O-A
I/O-B
1
6
1
6
7
8
5
10
5
10
UFB-A
UFB-B
6
5
18
D+
D+
D-
D-
3
4
MF-A
MF-B
2198-D -ERS
Dual-axis Inverter
(front view)
2
1
Item
Description
1
Motor cable clamp
2
Ground lug
3
Motor feedback (MF) connector - A
4
Motor feedback (MF) connector - B
5
Universal feedback (UFB) connector - A
6
Universal feedback (UFB) connector - B
7
Digital inputs (IOD) connector - A
8
Digital inputs (IOD) connector - B
9
Ethernet (PORT1) RJ45 connector
10
Ethernet (PORT2) RJ45 connector
Kinetix 5700 Dual-axis Inverters 3
MOD
NET
2
1
Clearance right of the
I/O-A
I/O-B
1
6
1
6
drive is not required.
5
10
5
10
UFB-A
UFB-B
D+
D+
D-
D-
MF-A
MF-B
100 mm (3.94 in.) clearance
below drive for airflow and
installation.
DC+
19
DC–
24V–
20
24V+
1
9
SB+/NC
S1A
SCA
S2A
SB-
S1B
SCB
S2B
8
16
2198-D -ERS
2198-D -ERS
Dual-axis Inverter
Dual-axis Inverter
(bottom view)
(top view)
Item
Description
11
Zero-stack mounting tab/cutout
12
Module status indicator
13
Network status indicator
14
LCD display
15
Navigation push buttons
16
Link speed status indicators
17
Link/Activity status indicators
18
Safe torque-off (STO) connector
19
DC bus (DC) connector
20
24V control input power (CP) connector
21
Motor brake (BC) connector - A
22
Motor power (MP) connector - A
23
Motor power (MP) connector - B
24
Motor brake (BC) connector - B
25
Cooling fan
21
22
23
24
25
25

Advertisement

loading