Override Mode

In the event of component failure or loss of system power, your slide-out can be manually overridden and
retracted for travel.
NOTE: At any time during the override procedure, the unit will exit this mode if the room has not been
moved for five (5) minutes.
NOTE: For major faults, only 1510000236 control will automatically enter "Emergency Jog" mode when
motor movement is not detected by the control box in either direction during room actuation.
When in "Emergency Jog" mode, the control will jog both motors in the direction the rocker switch
is pressed (IN or OUT). The rocker switch may need to be pressed multiple times to fully retract or
extend the room. Take the unit to an OEM authorized dealer for service.
NOTE: The control box will return to normal operation mode after 5 minutes of inactivity or by cycling
power to the control box. Use TIP Sheet 82-S0544 to reset control box 1510000276

Manual Emergency Retract Mode

In the event that power is lost to the slide-out motor(s) the room can be manually retracted by following
these steps:
1.
You will need to gain access from either the inside or outside (whichever is more convenient) of the
coach to the vertical channel assembly. The motors are currently located at the top of the channel.
If applicable, remove the top screw from the bulb seal at the top of the vertical channel (Fig. 10A).
2.
3.
Pull down the bulb seal and remove the motor cover (Fig. 11). The motor cover may stick to the bulb
seal.
Using a pick tool, remove the end of the retaining spring from the motor spring clip (Fig. 12A).
4.
5.
Unplug the motor from the harness and remove the motor by lifting it up and out.
Repeat steps 1-5 for the other side.
6.
Push the room into the retracted position.
7.
8.
Secure the room in place by either:
A. Re-installing the motors. Make sure the end of the retaining spring is re-hooked to the motor
spring clip (Fig. 12).
B. Torque the motor retaining screw to 40 in lbs. (Fig. 10) with the motor retainer fully engaged.
C. Use a travel lock (2 x 4 cut to size).
9.
Have the slide-out room serviced by the OEM authorized dealer as soon as possible. Do not operate
room until service is complete, as damage to the room may result.
NOTE: For major faults, the control will automatically enter "Emergency Jog" mode when motor movement
is not detected by the control box in either direction during room actuation. When in "Emergency
Jog" mode, the control will jog both motors in the direction the rocker switch is pressed (IN or OUT).
The rocker switch may need to be pressed multiple times to fully retract or extend the room. Take
the unit to an OEM authorized dealer for service.
Fig. 10