B. 1510000276 control. With the switch in the left position (as shown) the control will be in bypass
(not looking for a park brake input signal). With the switch in the right position the control will be
looking for a park brake signal input.
6.
If using the park brake feature, route the park brake input harness from the park brake signal source to
the control box.
NOTE: It is important that the slide-out motors be plugged in to the proper receptacle at the control box.
See (Fig. 7) below for proper slide-out motor designation. Failure to properly connect the motors to
the control will result in problems for future troubleshooting. (The control will identify the incorrect
motor during a fault).
7.
Route and attach the proper gauge wire from the control to the 12V DC battery. It is recommended
that this circuit be protected with a 30 amp fuse. Wire must be sized so that a minimum of 12.5 VDC is
measured at the control while under load.
Fig. 5
Rear
Rev: 05.24.2016
Fig. 6
Left
Motor 1
Motor 2
Right
Wire Gauge
Fig. 7
Roadside
Curbside
Page 5
Maximum Length
16
10 feet
14
15 feet
12
25 feet
10
40 feet