TABLE OF CONTENTS System Information Component Descriptions Installation General Requirements Mechanical Components Electrical Components Programming Setting the Retracted Stop Point Setting the Extended Stop Point Installation Issues Operation Prior To Moving the Slide-Out Room: Extending the Room Retracting the Room Preventative Maintenance Troubleshooting Override Mode...
Installation General Requirements • Power and wiring MUST be such that there is not less than 10.5 running volts supplied at the motor leads under maximum load. • Slide system controls MUST come from Power Gear. Controls supplied by other companies will void warranty.
Lift the slide room box into the coach opening and push in until the mounting flange meets the exterior wall. Verify the weight of the room is supported by the floor rollers and not the slide-out mechanism (Fig. 2). NOTE: If the room is not completely supported by the floor rollers, you will hear a slight “popping” sound as the room settles on to the rollers.
Page 5
B. 1510000276 control. With the switch in the left position (as shown) the control will be in bypass (not looking for a park brake input signal). With the switch in the right position the control will be looking for a park brake signal input. If using the park brake feature, route the park brake input harness from the park brake signal source to the control box.
Programming NOTE: When retracting or extending, the switch will need to be depressed and held for 2 seconds after the room stops moving. Failure to do so will cause the stops to NOT be set. Always make sure that the slide-out room path is clear of people and objects before and during operation of the slide-out room.
Operation Always make sure that the slide-out room path is clear of people and objects before and during operation of the slide-out room. Always keep away from the slide rails when the room is being operated. The gear assembly may pinch or catch on loose clothing causing personal injury.
Troubleshooting This control has the ability to detect and display several faults. When a fault is detected, the room movement may stop and 2 different LEDs on the control box will flash in a pattern. • The Fault Code LED (Fig. 9) on the rocker switch will flash RED a number of times corresponding to the number of red flashes on the control box (Fig.
Override Mode In the event of component failure or loss of system power, your slide-out can be manually overridden and retracted for travel. NOTE: At any time during the override procedure, the unit will exit this mode if the room has not been moved for five (5) minutes.
Alternate Overrides It may be possible to manually retract the room by accessing the ½” square drive tube at the bottom of each vertical channel assembly. This will only be possible if there is access to this area. Using a ½” 8-point star socket (Fig. 13) and alternating from one side to the other, turn the ½” square drive tube to bring the room in.
Page 11
Fig. 17 - Wiring Information for Control Box 151000276 Page 11 Rev: 05.24.2016 Slim Rack Slide-out Manual...
Page 12
Fig. 18 - Wiring Information for Control Box 151000236 Page 12 Rev: 05.24.2016 Slim Rack Slide-out Manual...
Page 14
The contents of this manual are proprietary and copyright protected by Lippert Components, Inc. (“LCI”). LCI prohibits the copying or dissemination of portions of this manual unless prior written consent from an authorized LCI representative has been provided. Any unauthorized use shall void any applicable warranty. ...