Module Status Leds; Alarms - Imagine communications Selenio 6800 HUC6800+C Installation And Operation Manual

Broadcast upconverters
Table of Contents

Advertisement

Chapter 3: Operation

Module Status LEDs

Note
If the LED is flashing red,
please contact your customer
service representative.

Alarms

50
The HUC6800+ and HUC6800+C modules do not have any card-edge
alarms. Instead, module status LEDs on the corner of the module light
up if an error is detected. See
these LEDs, and
Table 3-7
Alarms are usually logged and monitored within software control
applications such as +PilotLite or CCS Pilot. See the appropriate
software control user manual or online help for more information.
Table 3-7. LED Color and Meaning
LED Color
Meaning
Sequence
Off
There is no power to the module; the module is not
operational.
Green
There is power to the module; the module is operating
properly.
Red
There is an alarm condition.
Flashing Red
The module has detected a hardware/firmware fault.
Amber
The module is undergoing configuration.
Table 3-8
describes the specific alarms for HUC6800+ and
HUC6800+C modules. You can only identify specific alarms using a
software control application.
Table 3-8. HUC6800+ Alarms
Alarm Name
SDI IP Video Present
RefLockedAlarm
RefStdMismatch
Figure 3-2 on page 48
for a definition of the LED colors.
Alarm Description
Loss of SDI input video
Loss of locked reference
Mismatch between reference
video and video standard
HUC6800+ Installation and Operation Manual
for the location of
Alarm Level
Major
Major
Major

Advertisement

Table of Contents
loading

This manual is also suitable for:

Selenio 6800 huc6800

Table of Contents