Adjusting The Temperature; Temperature Mode; Temperature Sensor Error Codes - Marvel ML24BN Series Installation, Operation And Maintenance Instructions

Table of Contents

Advertisement

USING YOUR ELECTRONIC CONTROL - INDOOR MODELS

Adjusting the temperature:

To set or check the set-point temperature (with the control
out of sleep mode), press the "-" or "+" keypads. "SET" will
be indicated on the user interface panel and the current
set-point temperature will display and flash. Subsequent
presses of the "-" or "+" keypads will adjust the temperature
colder or warmer respectively. When you have reached
your desired set-point temperature, press the "On/Off" key-
pad to accept, or do nothing and the "Set" mode will time-
out in 10-seconds accepting the displayed temperature as
the new set-point.
The available set-point temperature range for your appli-
ance is 34°F (1.2°C) to 60°F (15.6°C). If you attempt to
adjust the temperature outside of this range you will receive
an audible notification.
CAUTION
!
If you are using the appliance as a refrigerator for perish-
able foods, the set-point temperature should be set be-
tween 34°F and 42° F (1.2° C and 5.7° C).
When initially loading your product with warm contents, it
may take up to 48-hours for the storage compartment tem-
perature to stabilize.
When making temperature set-point changes, it may take
up to 24-hours for the stored contents to stabilize at your
new set-point temperature.
Sensor
Displayed Code
Single Zone
Temperature
Sensor
Defrost Sensor
Factors that affect the storage compartment stabilized
temperature:

Temperature mode:

The temperature mode is preset from the factory in Fahren-
heit (°F) but you have the option to change it to Centigrade
(°C). To change the mode, press and hold the "-" keypad,
while pressing the "+" keypad, then release the "-" keypad.
The temperature will now be displayed in Centigrade (°C).
Repeat the procedure to change the temperature mode
back to Fahrenheit (°F).

Temperature Sensor Error Codes

The temperature sensors are monitored continuously. Any
OPEN or SHORTED circuit condition will initiate an
ERROR CODE as listed below:
Temperature Sensor Error Codes
Error Description
Failed temperature sensor in the single
zone compartment. Can lead to
unwanted storage temperatures and/or
spoiled perishable goods.
Failed defrost temperature sensor.
Causes unit to not defrost properly and
can create large frost build-up. Can lead
to water damage to the unit and
surrounding floor.
9
Changes to temperature setting.
Room temperature changes.
Temperature of stored contents.
- Loading warm contents.
- Cold content load will delay the change to a warmer
set-point temperature.
- Warm content load will delay the change to a colder
set-point temperature.
Usage, (number and duration of the door openings).
Installation of the appliance in direct sunlight or next to
a heat source.
Call service to have the
temperature sensor replaced and
remove all perishable goods from
compartment to prevent spoilage.
Unplug the power cord
immediately and call service to have
the defrost sensor replaced.
Action to Take

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mo24bn seriesMl24bnpMl24bnsMo24bns

Table of Contents