Motorola R-2001A Service Manual page 207

Communications system analyzer
Hide thumbs Also See for R-2001A:
Table of Contents

Advertisement

Table 22-1
.
IEEE-488 Interface Controllable Functions
Control/Measurement
Comment
Function Switch
Generate/
Power
Monitor/
Monitor
Modullllon Control
Cont inuou
s/O
FF/
BUR ST
Wldeband/
Narrowband Switch
Image
High/
Low Switch
Duplex Oscillator Switch
0- 10 MHz/O
FF/
45 MHZ
Keyboard
Numeric Entries
0-9
.
Can
be t
rans mitted
to
th
e
bus
.
Display Mode
Generate/ Mo
nitor
Meter ing
(N
o
te:
1)
Modula
tion
Spect
rum
Analyze
r
Dup
lex
Generator
A
F
Memo ry
Tone Memory
Frequency Counter
DVM
External
Watl
meter
IF
Scope AC
Scope DC
Remote Terminal
Mode
Unit
can also
d
isp
lay a subset
of
ASC
II
cha racte
rs
(nume
rals
0-9, upper
case alpha lette rs
A-Z, plu
s
other
symbols-
ASCI
I
characters
20
thru
5F
Hex a-
decimal)
enables
di spl
ay o
f
operato
r
messages on CRT
d
isplay in a t ranspa rent
ter-
m
i~
al
mode.
Function Mode
FM
(Note
:
1)
c
w
A
M
SSB/
DSB
SWP 1-10 MHz
SWP
0 .0 1-
1
MHz
Code Synthesizer Mode
PL/
OPL
PL/
DPL Invert
Tone
A
Tone
B
A/
8
Tone Remote
Control/
Measurement
Comment
1-
_______
::_:PL:_..:,Fr~eq.:!u::;•:::":::rcy
Frequency entry to be
RF Fre<>uencvl
OPL
Code
supplied
~Y prog ra~
j...:....-------.....!:~~~
Frequenc1es
not
available
1------,:,T:::onc:.:•:..:A,:...:,Fr:.:•.:.qu:::•::.n:.::!.cy
from memory
ta
ble.
Tone
B
Frequency
Time Sequence
Select
Seq
uences 1
throug
h
5 on ly
(Note: 2)
Wattmeter Element Select
External Modulation
Mod
ulation settable
to any
measu
rable level
Code
Synthesizer
Modulation
(0-20
KHz devia
tion in
10
Hz
steps)
(Note
:
3)
(0-90% A
M
in 0.1%
st
eps)
RF
level
RF
level
settab le
to
any
displayab le
level
(-1
40
to
+
11
dBm in
0
.1
d Bm steps
(Note:
3)
(Note:
4
)
Of1set
Oscillator
Adjust
Du
plex
Generator
Frequency
Settable from
fa
to
fo
±10
MHz in
1
KHz
step
s (Switch)
placed
in
0-1
0 MHz position)
(Nole:
3)
Scope Vertical
Step
Attenuator
0 .0 1, 0.1, 1, 10
volts
Horizontal Scope Sweep
1,
10, 100
m illi secon ds
1.
10,
100
m icroseconds
External
lnpu1 Power Meier)
Frequency Error
Deviation
+
or
-
%'
AM
.,.
or
-
External Frequency Count
External Power Meter
FWD/
REV
Notes:
(1)
May be
allected
by
other
con trols
(see
below)
.
(2) Sequence
5 timing
is
prog rammable under
IEEE
bus
con
trol
(3)
As
reading is
displayed,
LED corresponding
to appropriate
display
and function
mode
will illuminate.
(4)
The IEEE-Bus option. due to a change in
the RF
step
attenuator,
restricts
the
maximum RF output to
.,.1
1
dBm
.
NON-CONTROLLABLE FUNCTIONS
Since control and monitor functions of the inter-
face are implemented to obtain remote measure-
ment
capability
,
certain front panel
controls
are
not implemented
in
the
interface
due to
their
local operator
orientation
.
A list
of these oper-
ator oriented
controls are as
follows:
Power
On/
011
Power
Mode
Indicators
Display Focus
Display Intensity
Dispersion/
Sweep
Scope/
DVM Vertical
Vernier
Scope Trigger Level
Scope
Trigger Slope
Scope
Horizontal Sweep Vernier
Scope Vertical Position
Scope
Horizontal Position
Receiver
Squelch
Receiver
Volume
Zero Beat Indicator
RF
Scan
RF Memory Table
Tone
Sequences.
6, 7,
and 8
Entries
22-2
Deviati on
Lim it
Battery
Voltage Reading
Deviat ion Limit Alarm (Disabled
Unde
r
Rem ote Control
)
Attenuator
0
Indicator
Battery
Below Limit
Warning
BFO Frequency
Adjust
852
1·66

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-2002a

Table of Contents