CONDENSING UNIT SPECIFICATIONS (cont.)
Master-Bilt ®
Cond Unit/Comp
Model
Model
BHM-025NC
CRG3-0250-TF5
BHM-050VCC
CRN5-0500-TF5
BHMX0070B
F3AH-A078-IAV
BHMX0100B
F3AM-A105-CFV
BHMX0100C
F3AM-A105-TFC
BHMX0150B
F3AD-A151-CFV
BHMX0150C
F3AD-A151-TFC
BHMX015LC
CRA1-0150-TFC
BHMX0200B
CRD1-0200-PFV
BHMX0200C
CRD1-0200-TF5
BHMX020LB
CRD1-0200-PFV
BHMX020NB
CRD1-0200-PFV
BHMX020NC
CRD1-0200-TF5
BHMX020VCV
CRD1-0200-TF5
BHMX020YC
CRD1-0200-TF5
BHMX0250B
CRG3-0250-PFV
BHMX0250C
CRG3-0250-TF5
BHMX025LB
CRG3-0250-PFV
BHMX025NB
CRG3-0250-PFV
BHMX025NC
CRG3-0250-TF5
BHMX025VCV
CRG3-0250-TF5
BHMX025XC
CRG3-0250-TF5
BHMX0300B
CRK3-0325-PFV
BHMX0300C
CRK3-0325-TF5
BHMX0300CC
CRK3-0325-TF5
BHMX0300E
CR41KQ-TFD
BHMX030VCC
CRK3-0325-TF5
BHMX0400B
CRM3-0400-PFV
BHMX0400C
CRM3-0400-TF5
BHMX040VCV
CRK3-0325-TF5
BHMX0500B
CRN5-0500-PFV
BHMX0500C
CRN5-0500-TF5
BHMX050VCC
CRN5-0500-TF5
BHMX050VCK
CRN5-0500-TF5
BHMX050VCV
CRN5-0500-TF5
BHMX050WC
F3WD-0501-TFC
BHMZ0070B
FJAF-A078-CAV
BHMZ0100C
FJAM-A125-TFC
*Deduct 7% for each 10 degree rise over 90°F.
**MCA does not include evaporator amps for room temperature 35°F and above.
5/16 Rev. B 57-02497
BTU/HR Capacity
At Room Temp. With
a 10° TD, 90° Ambient
Compressor
Model
30
CRG3-0250-TF5
17907
CRN5-0500-TF5
38129
RSE4-0076-IAV
5760
REK3-0125-PFV
8540
REK3-0125-TFC
8540
CRA1-0150-PFV
10800
CRA1-0150-TFC
10800
CRA1-0150-TFC
11535
CRD1-0200-PFV
14049
CRD1-0200-TF5
14049
CRD1-0200-PFV
14417
CRD1-0200-PFV
14049
CRD1-0200-TF5
14049
CRD1-0200-TF5
14700
CRD1-0200-TF5
14049
CRG3-0250-PFV
17907
CRG3-0250-TF5
17907
CRG3-0250-PFV
18766
CRG3-0250-PFV
17907
CRG3-0250-TF5
17907
CRG3-0250-TF5
17907
CRG3-0250-TF5
17907
CRK3-0325-PFV
23419
CRK3-0325-TF5
23419
CRK3-0325-TF5
23419
CR41KQ-TFD
23419
CRK3-0325-TF5
23419
CRM3-0400-
30337
PFV
CRM3-0400-TF5
30337
CRK3-0325-TF5
23419
CRN5-0500-PFV
38129
CRN5-0500-TF5
38129
CRN5-0500-TF5
38129
CRN5-0500-TF5
41218
CRN5-0500-TF5
38129
CRN5-0500-TF5
38700
RS55C1E-CAV
6727
RS70C1E
7880
Base
Size
(See
pp.
Ref.
39-41) H.P.
R-22
C
2.5
R-22
C
R-22
A
.75
R-22
N
R-22
N
R-22
N
1.5
R-22
N
1.5
R-22
C
1.5
R-22
C
R-22
C
R-22
C
R-22
C
R-22
C
R-22
A
R-22
C
R-22
C
2.5
R-22
C
2.5
R-22
C
2.5
R-22
C
2.5
R-22
C
2.5
R-22
A
2.5
R-22
C
2.5
R-22
C
R-22
C
R-22
C
R-22
C
R-22
C
R-22
C
R-22
C
R-22
A
R-22
C
R-22
C
R-22
C
R-22
E
R-22
A
R-22
C
R-404A
A
.75
R-404A
N
30
Connections
Liquid Suction
MCA
1/2
7/8
22
5
5/8
7/8
51
3/8
5/8
15
1
3/8
5/8
15
1
3/8
5/8
15
3/8
7/8
24
3/8
7/8
20
3/8
5/8
20
2
3/8
5/8
29
2
3/8
5/8
23
2
1/2
7/8
28
2
3/8
5/8
24
2
3/8
5/8
18
2
3/8
5/8
13
2
5/8
7/8
23
1/2
7/8
31
1/2
7/8
24
1/2
7/8
31
1/2
7/8
28
1/2
7/8
22
1/2
7/8
23
1/2
7/8
22
3
1/2
7/8
45
3
1/2
7/8
45
3
1/2
7/8
45
3
1/2
7/8
10
3
1/2
7/8
39
4
5/8
7/8
49
4
5/8
7/8
45
4
5/8
7/8
26
5
5/8
7/8
49
5
5/8
7/8
45
5
5/8
7/8
51
5
5/8
7/8
51
5
5/8
7/8
50
5
3/8
1 1/8
50
3/8
5/8
15
1
3/8
7/8
15
Voltage
200-230/60/3
200-230/60/3
208-230/60/1
208-230/60/1
208-230/60/3
208-230/60/1
208-230/60/3
208-230/60/3
208-230/60/1
200-230/60/3
208-230/60/1
208-230/60/1
200-230/60/3
200-230/60/3
200-230/60/3
208-230/60/1
200-230/60/3
208-230/60/1
208-230/60/1
200-230/60/3
200-230/60/3
200-230/60/3
208-230/60/1
200-230/60/3
200-230/60/3
460/60/3
200-230/60/3
208-230/60/1
200-230/60/3
200-230/60/3
208-230/60/1
200-230/60/3
200-230/60/3
200-230/60/3
200-230/60/3
208-230/60/3
208-230/60/1
208-230/60/3

Advertisement