Index Definitions······································································2 Factory Default Settings··················································· 3 Handing Information ······················································· 3 Important Notes ····························································· 4 Change Master Code······················································· 5 Add Credentials······························································ 5 Add a User Code Add Multiple User Codes Add User Keycards Delete Credentials··························································· 7 Delete User Code Delete User Keycard Reset to Factory Default Settings System Settings ·····························································...
Definitions • Credential: The lock requires a valid credential to operate. A credential can be a Master Code, User Code, or Keycard/Fob. • LED Indicator: The LED indicators are located around the keypad of the lock. Lock flashes green LED and/or dependent on inputs.
Factory Default Settings Master Code: 123456 Penalty Time: 1 minute 30 seconds after 5 invalid entries Dual Verification Mode: Disabled Sound: Enabled Handing Information - IMPORTANT Handing must be set before programming lockset. It will not allow you to program lockset until handing is set. Steps 1.
Important Notes • To wake up the touch keypad from idle mode, gently swipe or tap the keypad. • While in Factory Default Settings, the lock will flash and then green. Any credential will open the lock until a Master Code in programmed into the lock.
Change Master Code Key Sequence For example, to change Master Code to “555555”, press: Notes • Factory Default Setting’s Master Code is 123456. It must be changed with the user’s own Master Code immediately. • Manufacturer assumes no liability, direct or indirect, due to failure to change Master Code. •...
Add Multiple User Codes Key Sequence User Code Key Sequence Additional User Codes Key Sequence: For example, to add User Codes “202020”, “303030”, and “404040”, press: Notes • The input of additional credentials must start before lock goes into Idle Mode (12 seconds). If the lock goes into Idle Mode, start the key sequence from the beginning.
Notes • Keycards/Fobs can be added interchangeably with User Codes. • Multiple Keycards/Fobs can be added during the same programming sequence (like Additional User Codes Key Sequence). • To exit, press asterisk (✴) or wait until the lock goes into Idle Mode (12 seconds). Delete Credentials Delete User Codes Key Sequence...
Reset Lock to Factory Default Settings Key Sequence Notes • All credentials will be deleted, and the lock will reset to Factory Default Settings. System Settings Dual Verification Mode Key Sequence Notes • Dual Verification Mode, when enabled, requires 2 valid credentials to operate the lock. •...
Reset Lock to Factory Default Settings without a Master Code Steps 1. Unscrew the back cover. 2. Locate the reset button on the battery holder. 3. Press and hold the reset button. After approximately 4 seconds, the lock will beep 2 times, and you can release the reset button.