XCE9000 Software Specifications
XCE9000 is a multidimensional electronic keypad lock, in addition to the keypad there is the remote
control emergency device for emergency action (lock down mode). This will immediately lock down all
doors associated with the remote control.
Passwords and authorizations:
Master Code:
The highest level password, you can set all the lock functions. Master Code can only be changed,
cannot be deleted. Factory Master Code is 1, 2, 3, 4, 5.
You must change the password before you use, lock will not program without changing the
Master Code. Password length can be 4 to 6 digits, all passwords are the same code length as
the Master Code. Once you change the code length of the Master Code, all previously entered
passwords will be cleared.
Service Code:
Password address is 01 to 10, and reusable. After entering the User Code the door will be relock
in 5 seconds after opening. Note: Address refers to a location in the lock memory‐ if the code is
programmed using an address from 01 to 10‐ the lock knows it is a Service Code for example.
Office Code:
Password address is 11 to 90, and reusable. Entering the Office Code will unlock the door and
keep the door open. Entering the Office Code again will lock the door and keep the door locked.
Emergency Code:
Password address is 91 to 99, and reusable. The Emergency Code is used to override the lock
down mode initiated by triggering the remote control emergency device, you must enter the
Emergency Code to release the door and stop the LED flashes.
Each user's password is unique and different. Using the same password will be rejected.
Password addresses are 01 to 99 for the Service Codes, Office Codes and Emergency Codes.
The password addresses determines the type of password.
Except for the Master Code, all password addresses are empty when shipped from the factory
or if the lock is reset.
Remote control emergency device and emergency lock status:
The purpose of the remote control is for locking the door down (lock down mode) in
emergencies only. The remote control does not release the lock down mode; it only initiates the
lock down mode.
The effective range for remote control is 75 feet inside and 25 feet outside.
When the door is in lock down mode the red warning LED will flash 3 times per second.
In the lock down mode you can still enter Master Code, User Code, and Office Code to unlock
the door, but it does not release the lock down mode.
Entering the Emergency code will deactivate the lock down mode and stop the LED flashing.