Rosemount Manifolds
Figure 23. Rosemount 304RT Natural Gas 5-Valve Flange
A
8.50
(216)
max open
∅
A.
0.281 mounting holes (2)
1
B.
/
-in. NPT test (plugged) (2)
4
Note: Manifold handle assembly may vary slightly from image shown. All valve handle assemblies provide the same function and meet all stated drawing
dimensions.
Dimensions are in inches (millimeters).
Figure 24. Rosemount 304RW 3-Valve Wafer Manifold
Instrument side
4.88
(124)
max open
1.25
(32)
Process side
3
A.
/
–16 UNC mounting holes (2)
8
1
B.
/
–14 NPT process connection (2)
2
Note: Manifold handle assembly may vary slightly from image shown. All valve handle assemblies provide the same function and meet all stated drawing
dimensions.
Dimensions are in inches (millimeters).
26
Instrument side
2.126
(54)
1.13
(29)
Process side
A
Flange Conventional Manifold
4.50
(114)
max open
1
C.
/
-in. NPT vent
4
7
/
D.
20
UNF mounting holes (4) on a 2.125 x 1.625
16
–
–
9.13
(232)
max open
B
1.50
(38)
3.35
(85)
August 2016
B
3.74
(95)
C
D
in. hole pattern
–
EmersonProcess.com/Rosemount