Samson TROVIS 6600 Mounting And Operating Instructions
Samson TROVIS 6600 Mounting And Operating Instructions

Samson TROVIS 6600 Mounting And Operating Instructions

Automation system. web terminal
Hide thumbs Also See for TROVIS 6600:

Advertisement

TROVIS 6600 Automation System
TROVIS 6616 Web Terminal
®
®
Electronics from SAMSON
Electronics from SAMSON
Mounting and
Operating Instructions
EB 6616 EN
Firmware version 1.30
Edition February 2016

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TROVIS 6600 and is the answer not in the manual?

Questions and answers

Summary of Contents for Samson TROVIS 6600

  • Page 1 TROVIS 6600 Automation System TROVIS 6616 Web Terminal Mounting and Operating Instructions EB 6616 EN Firmware version 1.30 ® ® Electronics from SAMSON Electronics from SAMSON Edition February 2016...
  • Page 2 Definition of signal words DANGER! NOTICE Hazardous situations which, if not Property damage message or mal- avoided, will result in death or seri- function ous injury Note:  WARNING! Additional information Hazardous situations which, if not avoided, could result in death or seri- Tip: ous injury Recommended action...
  • Page 3: Table Of Contents

    Contents Important safety instructions ................4 Overview of the TROVIS 6600 Automation System .........4 Network expansion (without repeaters, hubs etc.) ..........5 Cable recommendation ..................5 Power supply ....................5 Notes concerning TROVIS 6616 Web Terminal ..........5 Technical data ....................6 Installation ....................7 Start-up ......................8 Restarting the Setup Wizard .................10 6.2 Configuring Auto Start .................12 Operation ....................13...
  • Page 4: Important Safety Instructions

    Important safety instructions 1 Important safety instructions − The web terminal is to be mounted, started up or operated only by trained and experi- enced personnel familiar with the product. According to these mounting and operating instructions, trained personnel refers to individuals who are able to judge the work they are assigned to and recognize possible dangers due to their specialized training, their knowledge and experience as well as their knowledge of the applicable standards.
  • Page 5: Network Expansion (Without Repeaters, Hubs Etc.)

    Notes concerning TROVIS 6616 Web Terminal Associated software Operating system Android 4.0.3 with browser Part of TROVIS 6616 Web Terminal Application Microbrowser for Android version 1.6.30.142 and higher Graphical project TROVIS 6690 management tool (not included in the scope of delivery) Web Terminal Editor TROVIS 6693 (not included in the scope of delivery) 2.1 Network expansion (without repeaters, hubs etc.) Ethernet 100BaseT typ. LAN 2.2 Cable recommendation...
  • Page 6: Technical Data

    Technical data 4 Technical data Power supply Power supply 24 V DC or Power over Ethernet (PoE) Power consumption 7.4 W a) Wire cross-section stranded with ferrule without plastic sleeve, max. 1.5 mm² b) Wire cross-section stranded with ferrule with plastic sleeve, max. 0.5 mm² Temperature range Operation 0 to 50 °C Transportation and storage 0 to 70 °C Relative humidity 10 to 90 %, non-condensing...
  • Page 7: Installation

    Installation 5 Installation The web terminal is designed for panel mounting with the front dimensions 208 x 144 mm. Install as follows: Î Make panel cut-out with the dimensions 186 x 123 mm. Î Slide the web terminal from the front with the ventilation slits facing upward into the panel cut-out. Î Clamp the web terminal from the back against the control panel using the four supplied clips.
  • Page 8: Start-Up

    We recommend using a PoE (Power over Ethernet) switch. As a result, the external DC voltage supply for the TROVIS 6616 Web Terminal is not required. − A cross cable must be used to directly connect the TROVIS 6616 to TROVIS 6610. − To establish connection over active components (switch/hub), a 1:1 cable must be used. Refer to the manual of the components used for more information. The SAMSON start screen ap- pears approx. 25 seconds after the Ethernet connection is estab- lished. The Launcher starts auto- matically. The Setup Wizard appears 15 seconds after the Launcher starts on starting for the first time.
  • Page 9 Start-up 1. The web terminal has the de- fault IP address 172.30.240.100/16. To change the IP address, open the IP Address field and enter a new IP address. Press [Done] to confirm. 2. The netmask, DNS and gate- way configurations can be changed as described in step 3. Start the FTP server, if it is not already activated, by check- ing the box.
  • Page 10: Restarting The Setup Wizard

    Start-up 6. Reboot the web terminal: Buttons: and [Reboot] 7. Confirm "Reboot system?" with [OK]. 8. Continue as described in sec- tion 6.2. 6.1 Restarting the Setup Wizard 1. Swipe the screen to the sec- ond page of the Launcher and select Settings. EB 6616 EN...
  • Page 11 Start-up 2. Press [Password] and enter the password using the num- ber pad. The password that is valid on the first start-up can be found on page 35. To avoid its unauthorized use, remove the page or make the password unreadable. Press [Done] after entering the password and confirm with [OK]. 3. Select [Start Wizard]. 4.
  • Page 12: Configuring Auto Start

    Start-up 6.2 Configuring Auto Start The application determined in Auto Start starts automatically on starting the web terminal. 1. Select [Auto Start] in the Launcher. 2. If the required application does not appear under "Ap- plication", e.g. MicroBrowser, press [Select] and select the required application. Note:  To use the TROVIS MOBILE application in- stead of the MicroBrowser application, select "Browser". 3. Activate Auto Start by select- ing "ON"...
  • Page 13: Operation

    Operation 7 Operation The start page appears when no users are logged in. Status bar: SAMSON AG User level: 0 = Read only 1 = Read/write access 2 = Almost all privileges 3 = Administrator AT = Outdoor temperature (optional) Date Time Toolbar = Back = Open main menu = Login status: not logged in = Login status: logged in Open login page...
  • Page 14: Login

    Operation 7.1 Login Î Enter password in "Enter password" field. Î Press OK. Note:  The password determines which user level applies. After logging in: The login status changes to logged in. The key indicates which user level is active. (only in user level 2 and 3) Date and time of TROVIS 6610 CPU Module can be changed in user level 3 (almost all privileges)
  • Page 15: Main Menu

    Operation 7.2 Main menu Î Open main menu. Button (toolbar): The main menu of the master for the SAMSON TROVIS 6693 Web Terminal Editor is shown in this exam- ple. If the system is made up of just one graphic, the plant im- age is directly shown after opening the main menu.
  • Page 16 Operation Viewing the course of a data point in a graph Î Select the data point from the bottom left-hand list. Î Move the data point into the middle list. Button: Î Load the start and end dates of the data point into the corresponding data entry fields. Button: Î Load the data point into the graph. Button: The course of the data point between the start and end dates is plotted. Restricting the time period of the graph Î...
  • Page 17: Online Data (Online Trend)

    Operation Exporting data Î Save data in CSV format to the internal memory or to an external memory (USB flash drive). Button: Exiting the graph Î Return to the main menu. Button: (top right) 7.3.2 Online data (online trend) Î Show online data. Data defined in the TROVIS 6693 Web Terminal Editor are shown. It is not possible to se- lect other data on the web terminal. Button (toolbar): Note:  Display range and logging time are de- termined when the web page is created in TROVIS 6693 Web...
  • Page 18: Configuring The Target Directory

    Operation Alternatively, the automatic scaling of the Y axis can be deselected to make the graph larger. Possible actions: − Change how graph is dis- played. − Stop data logging. − Export data. Changing how the graph is displayed Î Shift displayed graph section to the right or left Buttons: Î...
  • Page 19 Operation Saving data to a computer An FTP client (e.g. File Zilla) is required. Login data: Server: IP address of web terminal User name: Password: 0725 Port: 2121 Copying data to a USB flash drive 1. Insert the USB flash drive into the side USB port. 2. Go to the login page. 3. Open the configuration menu. Button: 4. Select "Options". 5. Select the [/mnt/usb_host] di- rectory by checking the box.
  • Page 20: Active Alarms

    Operation 7.4 Active alarms Î Show active alarms. Button (toolbar): The total number of active alarms as well as each indi- vidual alarm with the time and date of its activation are listed. Alarms that are no longer valid are removed from the list without any additional in- formation.
  • Page 21: I/O View Web Application

    Operation 7.5.1 I/O View web application The I/O View web application enables users to access the input and outputs of the TROVIS 6610 CPU Module and the connected TROVIS 6620 and TROVIS 6625 Modules without the TROVIS 6690 Graphical Project Management Tool. The signal states of the inputs can be read, while the states of the outputs can be also be changed over forced manual op- eration.
  • Page 22 Operation 2. Open configuration of the first switching time with --:-- - --:--. 3. Enter start and end times (steps of 15 minutes). Buttons: 4. Exit configuration. Button: Note:  The configuration can be exited without saving it. Button: The "Entry added" message confirms that the configura- tion has been saved. 5. Add another switching time, if required.
  • Page 23: Changing Switching Times

    Operation 7. Exit time program. Buttons: Note:  Exit the time program by pressing in the Windows version of the MicroBrowser. 7.6.2 Changing switching times 1. Select day of the week that you want to configure. EB 6616 EN...
  • Page 24 Operation 2. Open configuration of the switching time you want to change. 3. Enter start and end times (steps of 15 minutes). Buttons: Delete switching times. (white buttons between the times) 4. Exit configuration. Button: Note:  The configuration can be exited without saving it. Button: The display of the new switch- ing time confirms that the...
  • Page 25: Deleting Switching Times

    Operation 7.6.3 Deleting switching times 1. Select day of the week that you want to configure. 2. Delete switching times. Button: 3. Return to weekly overview. Button: EB 6616 EN...
  • Page 26: Creating Special Schedules

    Operation 7.6.4 Creating special schedules Special schedules allow separate switching times to be entered for certain days, for example for vacations or public holidays. 1. Open special schedule. Button: 2. Go to configuration of the first special schedule time by selecting --:-- - --:--. Configuring special schedule (ac- tivation) 3. Open the configuration of the start date.
  • Page 27 Operation 4. Enter start date. Buttons: Apply start date on an annu- al basis, if required. Button: 5. Exit configuration. Button: Note:  The configuration can be exited without saving it. Button: The display of the new start date confirms that the config- uration has been saved. 6. Enter the end date. Button: End ...
  • Page 28: Trovis Mobile

    TROVIS MOBILE Configuring schedule for vaca- tions or public holidays (deacti- vation) 8. Change from activation to de- activation. Button: [Special schedule (activation)] Enter the time for deactivation in the same manner as described for activation. 9. Return to weekly overview. Button: 8 TROVIS MOBILE The TROVIS MOBILE web application can be operated over the browser of the TROVIS 6616...
  • Page 29 TROVIS MOBILE 2. Enter the password using the number pad and confirm with [Go]. 3. Log in. Button: [Anmelden] 4. Select [Konfiguration] to change the language. EB 6616 EN...
  • Page 30 TROVIS MOBILE 5. Open [Sprachauswahl] and select Englisch. 6. Confirm message with [OK]. The website is restarted. 7. Reenter password and con- firm with [Login]. EB 6616 EN...
  • Page 31 TROVIS MOBILE 8. In [Process view] go to the re- quired data point. EB 6616 EN...
  • Page 32: Cleaning The Screen

    Cleaning the screen 9 Cleaning the screen 1. Open the TouchBlocker on the second page of the Launcher. A 60-second countdown be- gins to allow you to clean the screen without it reacting to touch. Note:  Press to display the TouchBlocker running in the background. 2. To terminate TouchBlocker, press and swipe it up out of the screen.
  • Page 33 EB 6616 EN...
  • Page 34 EB 6616 EN...
  • Page 35 Password 1732...
  • Page 36 SAMSON AG · MESS- UND REGELTECHNIK Weismüllerstraße 3 · 60314 Frankfurt am Main, Germany Phone: +49 69 4009-0 · Fax: +49 69 4009-1507 EB 6616 EN samson@samson.de · www.samson.de...

This manual is also suitable for:

Trovis 6616

Table of Contents