  • Page 1 ELECTRONIC PUMP CONTROLLER MODEL NO: EPC800 PART NO: 7230698 OPERATION & MAINTENANCE INSTRUCTIONS LS0714...
  • Page 2 This in-line device maintains water pressure from booster pumps by instantly sensing water usage and automatically starting or stopping the pump. 2. It protects the pump from running dry. The EPC800 has a built in safety circuit, which switches the pump OFF when there is no water flow. GUARANTEE This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase.
  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS 1. DO NOT attempt to modify or alter the controller in any way. 2. Observe all electrical precautions. DO NOT allow the EPC800 to be submerged. Ensure it is protected from the elements at all times. 3. Read and comply with all precautions specified in your pump manual.
  • Page 4: Electrical Connections

    EXTENSION CABLES The maximum length of cable should not exceed 25 metres, and the size of the conductors must be AT LEAST the same size as that on the EPC800. Ensure that all connections are well clear of the water.
  • Page 5: Installation

    INSTALLATION Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com...
  • Page 6: Operation

    The EPC800 is programmed to perform all the pump control operations automatically. • If you open the outlet tap the EPC800 will detect a drop in pressure and start the pump. When operational breakdowns occur, such as water loss, obstruction of the suction pipe, etc., the EPC800 recognizes the problem and the red “Failure”...
  • Page 7: Wiring Diagrams

    WIRING DIAGRAMS FOR CONNECTING THE EPC800 TO DIFFERENT KINDS OF PUMPS MOTORS Connection of single Connection of single Connection of three phase 220V pumps phase 220V pumps over phase 380V pumps (up to 1.1 Kw). 1.1 Kw through a remote through a remote control control switch.
  • Page 8: Troubleshooting

    TROUBLESHOOTING Problem Causes related to the EPC800. Other possible causes The pump The internal PCB is broken Voltage failure does not start Pump jammed Electric cables incorrectly wired The pump The internal PCB is broken Presence of leaks which are...
  • Page 9: Specifications

    SPECIFICATIONS Input Voltage 220-240V Frequency 50-60Hz Maximum Current Maximum Flow Rate 83 l/min Maximum Head 50 m Max. Water Temp. 60°C Protection Rating IP65 Maximum Operating Pressure 10 bar Maximum Temperature Rating 60°C Connection 1" BSP ENVIRONMENTAL RECYCLING POLICY Through purchase of this product, the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment, recycling &...
  • Page 10: Declaration Of Conformity

    DECLARATION OF CONFORMITY Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com...
  • Page 11 ACCESSORIES Layflat Hoses Assorted Hose Clip Set - CHT672 • Available in 100 metre coils or per • 26 piece assorted hose clip set in meter. various sizes, Including. 8 x16mm, • Available in 1” - 3” Diameter. 6 x 22mm, 4 x 25mm, 2 x 28mm, 2 x 35mm &...