Download  Print this page

Panel Mounting - Honeywell CentraLine LYNX LON CLLYUL1012S Product Data

Programmable vav/unitary controllers
Hide thumbs

Advertisement

1
1 1 1 1 1 1 1 1 1 2
9
0
1 2 3 4 5 6 7 8 9 0
159 149
1 2 3 4 5 6 7 8

PANEL MOUNTING

HOLE (4 X 4.5)
Fig. 4. Duct mounting, dimensions in mm
(CLLYVL0000AS, CLLYVL4022AS, and CLLYVL6436AS)
211
164
2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 4
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0
146 128
PANEL MOUNTING
HOLE (4 X 4.5)
1 2 3 4 5 6 7 8
9
Fig. 5. Duct mounting – controller and actuator,
dimensions in mm (CLLYVL6436AS, only)
122
105
1
1
1 1 1 1 1
2
2
2
2
2
3
4
5 6 7 8 9 0 0
1 2
3
4
159
149
DEPTH = 57
1 1
1
2
3 4 5 6 7 8 9 0
1
2
PANEL MOUNTING
HOLE (4 X 4.5)
Fig. 6. Panel mounting, dimensions in mm
(CLLYUL1012S, CLLYUL4024S, and CLLYVL4024NS,
only; CLLYUL4024S, and CLLYVL4024NS shown)
Panel Mounting
The controller enclosure is constructed of a plastic base plate
and a plastic factory-snap-on cover.
LYNX LON PROGRAMMABLE, VAV/UNITARY CONTROLLERS – PRODUCT DATA
211
105
49
DEPTH = 57
262
47
DEPTH = 57
1
1 1 1 1 1 1 1
0
1
2 3 4 5 6 7
122
105
1
1
1 1 1 1 1
2
2
2
2
2
3
4
5 6 7 8 9 0 0
1 2
3
4
159
149
DEPTH = 57
1 1
1
2
3 4 5 6 7 8 9 0
1
2
PANEL MOUNTING
HOLE (4 X 4.5)
21
159
146 139
128
DEPTH = 57
1 2 3 4 5 6 7 8
11
159
139
128
DEPTH = 57
1 2 3 4 5 6 7 8
Fig. 7. Panel mounting, dimensions in mm
(CLLYVL6438NS and CLLYUL6438S)
NOTE:
The controller is designed so that the cover does
not need to be removed from the base plate for
either mounting or wiring.
The controller mounts using four screws inserted through the
corners of the base plate. Fasten securely with four screws.
The controller can be mounted in any orientation. Ventilation
openings are designed into the cover to allow proper heat
dissipation, regardless of the mounting orientation.
DIN Rail Mounting (Models without Actuator)
To mount the CLLYUL1012S, CLLYUL4024S, and
CLLYUL6438S or CLLYVL6438NS controller onto a DIN rail,
see Fig. 8 and perform the following steps:
1. Holding the controller with its top tilted in towards the DIN
rail, hook the two top tabs on the back of the controller
onto the top of the DIN rail.
2. Push down and in to snap the two bottom flex connectors
of the controller onto the DIN rail.
5
2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 4
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0
CLLYVL6438NS
1
1 1 1 1 1 1 1
9
0
1
2 3 4 5 6 7
164
174
164
2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 4
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0
CLLYUL6438S
1
1 1 1 1 1 1 1
2 3 4 5 6 7
9
0
1
EN0Z-0957GE51 R0615

Advertisement

loading