AT Command Reference

8
AT Command Reference
Command
AT**
A/
AT\A<n>
AT\B<n>
AT%B<n>
32
Description
Start of the flash load function
Repeat the last command
The last command is repeated.
Select maximum MNP block size
Define maximum block size for error corrected MNP transmissions.
64 byte
AT\A0
128 byte (default)
AT\A1
192 byte
AT\A2
256 byte
AT\A3
Send "break" to the other i-modul Modem 336 LL 3.0
For connections that were not error corrected, the i-modul Modem 336 LL 3.0
sends a break signal to the other i-modul Modem 336 LL 3.0. The length of the
signal is: the specified parameter times 1/10 of a second.
For error corrected connections, the i-modul Modem 336 LL 3.0 sends a break
signal according to the active error correction protocol without considering a pa-
rameter specification.
If no connection is established or if a fax connection is active, an error message is
displayed.
1/10 second break signal
AT\B1
2/10 second break signal
AT\B2
3/10 second break signal
AT\B3
4/10 second break signal
AT\B4
5/10 second break signal
AT\B5
6/10 second break signal
AT\B6
7/10 second break signal
AT\B7
8/10 second break signal
AT\B8
9/10 second break signal
AT\B9
Switch key abort on and off during connection
Key abort is active. Each character on the TX line will result in an
%B0
interruption of the connection setup.
Key abort is deactivated. A connection setup can not be inter-
%B1
rupted manually. A connection setup can only be terminated via
DTR drop, internal canceling of the i-modul Modem 336 LL 3.0 (NO
DIALTONE, BUSY) or Timeout (NO CARRIER). (S-Registry 36, Bit 6)
(default)