Settings; P14 : Supply Air Flow Rate Offset - STIEBEL ELTRON LWZ 130 Operation And Installation

Centralised ventilation unit with heat recovery
Table of Contents

Advertisement

Available languages

Available languages

INsTALLATIoN

Settings

12. Settings
12.1 Parameter
Description
P1
Set room temperature
P2
Intensive ventilation runtime
P3
Passive cooling operating mode
P4
Reset filter
P6
Flow rate, stage 0
P7
Flow rate, stage1
P8
Flow rate, stage 2
P9
Flow rate, stage 3
P14 Supply air flow rate offset
P15 Humidity protection interval
P16 Start-up time for humidity measurement
P17 Extract air humidity limit
P18 Frost protection temperature
P19 Filter change interval
P22 Enable preheater
P24 Passive cooling release temperature
P25 Passive cooling blocking temperature
P26 Passive cooling hysteresis
P27 Temperature differential for enabling pas-
sive cooling
P28 Enable fan
P29 Appliance type
P30 Temperature for enabling frost protection
P31 Enabling of humidity-dependent flow rate
control
P70 Delete fault list
P80 Day
P81 Time
P82 Level of lighting
P83 Mode of backlighting
P84 Illumination duration
P85 Lower standard display
P28: Delivered condition OFF
„P14 : Supply air flow rate offset
Use this parameter to adjust the supply air flow rate during com-
missioning. The offset relates to standard ventilation. The offset
is converted internally as a percentage for the other fan stages.
Example
- Nominal flow rate (stage 2) : 125 m³/h
- Offset : 25 m³/h
Stage Set 
Off-
Set flow 
flow 
set
rate + 
rate
offset
0
50
1
90
2
125
25 125+25 = 150 150/125 = 1.2 125*1.2 = 150
3
180
44
|  LWZ 130 
Code
Unit
Min. Max.
A0
°C
A0
min
A0
A0
A1
m³/h
50
A1
m³/h
70
A1
m³/h
90
A1
m³/h
110
A1
m³/h
-100
A1
h
A1
min
A1
%
A1
°C
-5.0
A1
d
A1
A1
°C
5.0
A1
°C
5.0
A1
K
0.0
A1
°C
0.0
A0
A1
A1
°C
-5.0
A1
A1
A0
A0
00:00
A0
A0
A0
s
10
A0
Offset 
Internal set flow rate 
factor
= set flow rate * off-
set factor
50*1.2 = 60
90*1.2 = 108
180*1.2 = 216
LWZ 130
Options Stand-
5
28
1
240
0 | 1 | 2 | 3
0 | 1
100
120
140
180
100
1
24
5
15
5
95
15.0
1
365
0 | 1
15.0
15.0
5.0
5.0
On  | OFF
5.0
0 | 1
0 | 1
1
7
23:59
2
10
Auto | On | OFF
500
OFF | Time  | Set room
temperature  | Extract
air temp.  | Extract air
humidity
LWZ 130 Enthalpie
Min. Max.
ard
20
5
28
30
1
240
2
0
50
50
100
90
70
120
125
90
140
180
110
180
0
-100
100
1
1
24
5
5
15
65
5
95
2
-5.0
15.0
90
1
365
1
10
5.0
15.0
8
5.0
15.0
2
0.0
5.0
2
0.0
5.0
On
3
-3
-5.0
5.0
0
0
1
7
00:00
23:59
10
2
10
Auto
Auto | On | OFF
60
10
500
OFF
OFF | Time  | Set room
temperature  | Extract
air temp.  | Extract air
www.stiebel-eltron.com
Options Stand-
ard
20
30
0 | 1 | 2 | 3
2
0 | 1
0
50
90
125
180
0
1
5
65
2
90
0 | 1
1
10
8
2
2
On  | OFF
On
4
-3
0 | 1
1
0 | 1
0
10
Auto
60
OFF
humidity

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Lwz 130 enthalpie

Table of Contents