The accommodation is always too cold �������������������� 16 deposits. 6.10 The accommodation is always too hot ��������������������� 16 6.11 The accommodation is too cold in winter������������������ 17 6.12 The accommodation is too hot in winter ������������������� 17 | LWZ 304-404 Trend/LWZ 304 Integral www.stiebel-eltron.com...
Never splash the appliance with water or other liquids. Symbol Meaning Material losses WARNING Burns (appliance damage, consequential losses and environmen- There is a risk of scalding at outlet temperatures in ex- tal pollution) cess of 43 °C. www.stiebel-eltron.com LWZ 304-404 Trend/LWZ 304 Integral |...
(see chapter "Favourites"). When you are means of an integral electric emergency/booster heater. With a in the menu, the favourites display is no longer shown. mono mode design, the electric emergency/booster heater is acti- | LWZ 304-404 Trend/LWZ 304 Integral www.stiebel-eltron.com...
Page 5
With the function block, you can block the user interface for 60 seconds. Heating circuit pump: The pump symbol is displayed when a heating circuit pump is running. www.stiebel-eltron.com LWZ 304-404 Trend/LWZ 304 Integral |...
Then confirm your selection with the OK key. appliance runs in setback mode if no time programs are enabled. Only now does the appliance change to the new operating mode. | LWZ 304-404 Trend/LWZ 304 Integral www.stiebel-eltron.com...
"DIRECT LINE" appears. Confirm with "OK". Select the number of the required parameter. Confirm with "OK". You can select parameters 01 to 89. To make the direct line easier to use, the parameter designations are displayed along with their numbers. www.stiebel-eltron.com LWZ 304-404 Trend/LWZ 304 Integral |...
In the "ACTUAL VALUES" menu, actual values are displayed. See Turning the scroll wheel displays the highlighter that you can then the chapter "Menu structure" for a list of these. move to the required date. | LWZ 304-404 Trend/LWZ 304 Integral www.stiebel-eltron.com...
The previously shown display appears, i.e. dashes instead of numbers. Confirm again with OK. - on individual days ("MONDAY", ... , "SUNDAY") - from Monday to Friday ("MON - FRI") www.stiebel-eltron.com LWZ 304-404 Trend/LWZ 304 Integral |...
ROOM TEMPERA- 20 °C 20 °C circuit with mixer for underfloor heating system. TURE DAY (P01) Enter the "ROOM TEMPERATURES HC1" submenu for settings ap- plicable to the first heating circuit. | LWZ 304-404 Trend/LWZ 304 Integral www.stiebel-eltron.com...
Page 11
Note that parameter "Flow proportion" has an influence on heating curve "HC1". This means the heating curve is distinctly lower than the flow temperature curve. (see examples 1 and 2). The heating curve for "HC2" is a flow temperature curve. www.stiebel-eltron.com LWZ 304-404 Trend/LWZ 304 Integral |...
TIME Normally, the appliance controls when and for how long to venti- late. However, via the quick access option "VENTILATION STAGES" you can run ventilation outside the normal schedule. | LWZ 304-404 Trend/LWZ 304 Integral www.stiebel-eltron.com...
PCB. The software version indicates the appliance type. The explanation can be found in the installation instructions for qualified contractors. SOFTWARE ID "SOFTWARE ID" shows the consecutive number of the software. www.stiebel-eltron.com LWZ 304-404 Trend/LWZ 304 Integral |...
ANALYSIS WEDNESDAY 10 SEPT 14 16:27 H In the "ANALYSIS" submenu actual values are displayed that may FAULT be useful to the service department when troubleshooting. CODE NO. 001 PLS INFORM CUST SERVICE | LWZ 304-404 Trend/LWZ 304 Integral www.stiebel-eltron.com...
Clean the filter box (if present) attached to the outdoor air connector on the rear of the appliance. f Open the function module door. 1 Extract air filter 2 Supply air filter www.stiebel-eltron.com LWZ 304-404 Trend/LWZ 304 Integral |...
If water escapes from the appliance, shut it down immediately and notify your qualified contractor. 6.10 The accommodation is always too hot Reduce the low end temperature of the heating curve by the number of degrees the room temperature exceeds a comfortable temperature. | LWZ 304-404 Trend/LWZ 304 Integral www.stiebel-eltron.com...
You can set a fan program for this. Here you set the time during which the appliance runs in day mode. For the rest of the time, the appliance runs at the fan stage that you set in the "NIGHT STAGE" parameter. www.stiebel-eltron.com LWZ 304-404 Trend/LWZ 304 Integral |...
Set flow rate of the heat pump fan COMPRESSOR STARTS AMOUNT OF HEAT HEAT METER HTG DAY Amount of heat that was transferred by the heat pump to the heating circuit on this day. | LWZ 304-404 Trend/LWZ 304 Integral www.stiebel-eltron.com...
Page 19
Power drawn by the compressor since commissioning for supplying the DHW cylinder DIAGNOSIS SYSTEM STATUS POWER-OFF OVEN / FIREPLACE AIR HEAT EXCH. DEFR. EVAPORATOR DEFROST FAULT LIST www.stiebel-eltron.com LWZ 304-404 Trend/LWZ 304 Integral |...
Page 20
HEATING CURVE HC1 GRADIENT HC1 0.2 for underfloor heating system LOW END HC1 °C ROOM INFLUENCE HC1 FLOW PROPORTION HC1 MAX. SET VALUE HC1 °C | LWZ 304-404 Trend/LWZ 304 Integral www.stiebel-eltron.com...
Page 21
TIME UNSCHED. VENT TIME STAGE 0 1000 UNSCHED. VENT TIME STAGE 1 1000 UNSCHED. VENT TIME STAGE 2 1000 UNSCHED. VENT TIME STAGE 3 1000 www.stiebel-eltron.com LWZ 304-404 Trend/LWZ 304 Integral |...
Page 22
REL HUMIDITY CORRECTION CONTROLLER SOFTWARE VERSION SOFTWARE ID DELIVERED CONDITION OFF | ON APPLIANCE TYPE TIME / DATE TIME / DATE | LWZ 304-404 Trend/LWZ 304 Integral www.stiebel-eltron.com...
Page 23
EVAP. OUTLET TEMP. °C HOT GAS TEMPERATURE °C FLOW TEMPERATURE °C CONDENSER TEMP. °C RETURN TEMPERATURE °C COOLING TEMP. °C HIGH PRESSURE www.stiebel-eltron.com LWZ 304-404 Trend/LWZ 304 Integral |...
Page 24
DYNAMIC FACTOR P FACTOR I FACTOR D FACTOR OPENING EXV PRE-CTRL OPENING EXV Factory setting for stage of all fans is 0. | LWZ 304-404 Trend/LWZ 304 Integral www.stiebel-eltron.com...
Page 25
This device is filled with refrigerant R407C. Refrigerant R407C is a CFC greenhouse gas mentioned in the Kyoto protocol with a global greenhouse potential (GWP) = 1653. Never release refrigerant R407C to atmosphere. www.stiebel-eltron.com LWZ 304-404 Trend/LWZ 304 Integral |...
Page 26
NOTES | LWZ 304-404 Trend/LWZ 304 Integral www.stiebel-eltron.com...
Page 27
NOTES www.stiebel-eltron.com LWZ 304-404 Trend/LWZ 304 Integral |...