Maximum load ratings and electrical characteristics
of P series control panels
Maximum long term output current of P16 control panel:
(I
+ I
+ I
+ I
+AUX
+BELL
+PGM
BAT. CHARGE
Maximum long term output current of P32, P64 control panel:
(I
+ I
+ I
+ I
+BELL
BAT. CHARGE
+AUX
+PGM
Maximum current out of +AUX:
Maximum current out of +BELL:
Maximum current into -PGM:
Maximum current out of +PGM for P16:
Maximum current out of +PGM for P32, P64:
Maximum battery charging current:
Low battery voltage threshold:
Control panel disconnect battery when it's voltage is less than:
Minimum AC voltage on 20 VAC:
Note: with ~16 V on 20 VAC max DC current generated by
control panel power supply is 0,7A.
Maximum AC voltage on
20 VAC
Note: higher than
~22
V voltage can damage control panel
Maximum voltage on +AUX, +BELL, +PGM outputs:
Minimum voltage on +AUX, +BELL, +PGM outputs:
Maximum current of a fast blowing fuse used in battery circuit:
Max current of a slow blowing fuse used in primary AC circuit:
Maximum AC power consumption:

Keypad mounting

Use only self-tapping screws with a flat (countersunk)
head (3x30 PH) to mount keypad's plastic on the wall .
Make sure the screw is fastened completely and its
head is hidden in the plastic. Other shapes of screws
that are not completely screwed in, may touch keypad
electronics and cause damage of keypad.
Keypad
Operating temperature
Operating temperature range:
Calculated life expectancy at 40
for
P16, P32, P64 control panels:
Note: ambient temperature over 40
Note: poor ventilation of the cabinet increases ambient temperature.
Maximum load ratings and electrical
characteristics of PWR20
Maximum long term current out of PWR20:
(I
+ I
+ I
+BELL
BAT. CHARGE
+AUX
Maximum current out of +AUX:
Maximum current out of +BELL:
Maximum current into -PGM1:
Maximum battery charging current:
Module disconnect battery when its
voltage is less than:
12V battery
7Ah/20HR
Live
Neutral
Protective
wire
wire
Earth wire
L
N
PE
Main Protective
Earthing terminal
Primary winding: 230V AC 50Hz
Secondary winding:
Power supply
distribution board

Electrical characteristics and additional information

1,5 A )
2 A )
:
.
-10°C to +55°C
°C
ambient temperature:
°C
may reduce life expectancy.
Wiring of modules in large or high security level system
2,0A
2 A )
+1A
PWR20
+2A
-0,05A
0,35A
9,5V
Black
Red
X1
BAT
~20 VAC
Fuse
250mA
AC power transformer:
~
~
20V AC 50Hz

Restoring service PIN to default value

To restore default value (0000) for service PIN, follow these steps:
disconnect control panel from 20 V AC power supply;
1,5 A
disconnect control panel from back-up battery;
use a wire to short-circuit the -PGM and zone Z1;
2 A
connect control panel to 20 V AC power supply.
Service mode is now enabled and service PIN is restored to 0000. To reset user
+1 A
PIN follow the steps:
do not block service by pressing ENT;
+2,0 A
press arrow key to navigate in the menu;
-0,3A
go to: Main Menu/Settings/Users/Edit Users/ enter 0000 /Reset PIN to
+0,5 A
default/YES
+0,9 A
+0,35 A
10,5 V
Live
Neutral
9,5 V
wire
wire
L
N
~16 V
~22
V
Main Protective
Earthing terminal
+13,9 V
+12,0 V
3,15 A

System start-up with no 230V AC power

250 mA
Connect 12V battery to P
240 mA
series control panel by using a
BAT connector. Use the
jumper to close the shown pins
for 1 second. The system will
start operating; however, AC
loss trouble will be indicated.
Control panel has non-volatile memory to store all parameters, event log, and the
12 years
last control panel status. System status returns to the same status as it was before
the power supply was disconnected.
Overload of +BELL or + AUX.
Battery charging on
Low battery indicator
Module address LED
+BELL
COM -PGM1TMP COM
CLK-I
DAT-I
+AUX
CLK-O
DAT-O
COM from Pxx
CLK from Pxx
DAT from Pxx
+12V
+12V
+12V
+12V
COM
COM
COM
COM
CLK-O
CLK-O
CLK
CLK
DAT-O
DAT-O
DAT
DAT
Module
Control Panels P16, P32, P64
Protective
Earth wire
PE
20VAC
+BELL
Fuse
250mA
Jumper
Black
Red
12V battery
7Ah/20HR
Non-volatile memory
Outdoor siren's safe wiring
Use a transformer, other than a control panel, and a
rechargeable 12V 7Ah battery to power up PWR20. If
an alarm system includes PWR20, it is recommended
to wire an outdoor siren to the PWR20 terminals
+BELL, -PGM1, (-PGM2), and COM same as shown
on page 2. Failure of siren's internal battery or the siren
itself will not affect the performance of an alarm
system.
OVL
CHG
LOW
PWR20 – power supply module
MOD
with a bus repeater
Repetition of the system bus (KRbus) is a perfect
solution when some system modules (PROX8,
EXTx16) are placed outside the premises or in an area
that is not protected by detectors. It is recommended to
wire all outside proximity readers or keypads located
near the entry door to the repeated (by PWR20) bus.
An attempt to make a short circuit on the outside
module will make no affect to system's performance.
PWR20 will detect the short circuit on repeated bus
and will disconnect it from the main bus. Terminals
CLK-I and DAT-I are inputs for the main bus, terminals
CLK-O and DAT-O are outputs of the repeated bus. To
supply power to modules, PWR20 output +AUX must
be used.
Wiring manual
COM -PGM +PGM COM CLK DAT +AUX Z1 COM Z2
Wire
20VAC
+BELL
COM -PGM
Page 3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P16 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

P32P64

Table of Contents