Electrical Installation

Main Serial Interface

The optocoupled main serial interface is compatible with the following electrical
standards:
RS232
RS422 full-duplex

RS232 Interface

The main serial interface is used for communication with the Host computer and
allows transmission of code data.
It is always advisable to use shielded cables. The overall maximum cable length
must be less than 15 m (49.2 ft).
The following positions of the CBX510 spring clamp connector (row 4) are used
for RS232 interface connection:
As suggested above, the cable shield should be connected in the 'Shield' posi-
tion.
The RTS and CTS signals control data transmission and synchronize the con-
nected devices. If the RTS/CTS hardware protocol is enabled, the scanner acti-
vates the RTS output to indicate a message can be transmitted. The Host must
activate the CTS input to enable the transmission.
RTS/CTS lines should only be connected if the Main serial port handshaking is configure
for Hardware (RTS/CTS) (see section ).
28
Name
Function
SGND
Signal ground (isolated)
TX
Transmit
RTS
Request to send
RX
Receive
CTS
Clear to send
DX8210 Barcode Scanner