User Interface
Conveyer Direction Input
Select Trigger (Input 1) or Aux (Input 3) from the drop-down list. The selection
defines which digital input transmits information about the conveyor direction. The
conveyor direction is Forward when the selected input is active (default active
closed). If Input 1 is used the scanner Phase On LED also signals the direction state.
SW Divide Encoder Frequency
Select the check box to enable. If selected, the encoder frequency value is divided
by two before it is transmitted to the Host. This parameter only effects the value
contained in the <Encoder> field of the messages sent from the scanner to the
Host.
Message Definition
Header
Enter a message header in the field provided. A Header (up to 128 bytes) can be
defined and transmitted as a block preceding all messages sent from the scanner.
Character from NUL (00H) to ~ (7EH) can be used.
Trailer
Enter a message trailer in the field provided. A Trailer (up to 128 bytes) can be
defined and transmitted as a block following all messages sent from the scanner.
Character from NUL (00H) to ~ (7EH) can be used.
Heartbeat Enable
Select the check box to enable heartbeat.
Heartbeat Timeout
Enter a value in milliseconds. This parameter is available when the Heartbeat
parameter is enabled. It defines the amount of time between two message
transmissions. If the selected timeout expires and no transmission has occurred,
the Heartbeat message will be transmitted.
Heartbeat Message
Click
provided. This parameter is available only when the Heartbeat parameter is
enabled. This defines the Heartbeat message.
Click Submit to save your changes, or click Cancel to return to previous.
Code Field Length Setting
Select Fixed Length or Variable Length from the drop-down list. This parameter is
applied only to the <Barcode> field contained in two specific messages (Barcode
information and Diagnostics) of the protocol. The code field length (in number of
characters/digits) can be specified in order to be transmitted:
Add AIM Prefix
Select check box to enable. If enabled, it adds the AIM standard prefix to the
barcode to be sent to the host. No separator character will be added between the
AIM prefix and the barcode.
AM/PM Behavior
Select the check box to enable. If enabled, the Host is ready to receive the following
message:
where:
<COMMAND> = 'A' indicates that the Host starts working in AM mode / 'P'
indicates that the Host starts working in PM (default) mode
When working in AM mode:
each code is only filtered by the Encoder Timeout parameter;
the Purolator Custom Check parameter is not effective; the Heartbeat message will
never be transmitted; the transmitted message is not subject to padding with the
Fill Character and the output message format is the following:
128
to activate the Text Entry Tool and create a heartbeat message in the field
Variable: All possible code field lengths (in number of characters/digits)
allowed for the code selected are accepted
Fixed: The code is entirely transmitted even if it is longer than the defined
length. If shorter, it will be transmitted with the addition of the Fill Character.