Setup

Connect Jacketed Heated Hose

(Remote Mix Manifold Only)
NOTE: For all steps below refer to the illustration on the
next page.
Refer to your mix manifold manual for details when the
mix manifold (36) is remotely mounted.
1. Loosen the fittings (306) to remove the mix manifold
assembly (36). Install couplers (supplied with
heated hose) on fittings of circulation manifold (35).
2. Connect "A" and "B" material hoses to the fluid
circulation manifold (35) using necessary adapter
fittings (supplied with heated hose).
3. Connect the female quick-disconnect "Y" fitting
assembly (107) to the blue tubing quick-disconnect
from below the overflow bottles.
4. Connect the male quick-disconnect "Y" fitting
assembly (108) to the red tubing quick-disconnect
from the heater outlet.
5. Connect the glycol circulation tubing to the "Y" fitting
assemblies. Connect to the "Y" fitting assembly.
NOTE: The tubes and fittings are color coded. Make
sure all colors match when connecting the fittings.
6. Connect the mix manifold (36) to the remote
manifold carriage (109) and two screws (609).
7. Connect the "A" and "B" hoses to the mix manifold
(35) using necessary adapter fittings (supplied with
heated hose).
28
8. Connect the extension glycol tubing from the hose
bundle to the heater block (HB). Cut the tubing
squarely behind only one of the u-fittings. Connect
the two union fittings (610) to the hose tubing (one
red, one blue). Cut the red tubing (611) piece and
blue tubing (612) piece to length to fit between the
hose bundle and heater block, then tighten the
fittings.
9. Fill the circulation pump reservoir (306) with heating
fluid (50/50 mix of water/ethylene glycol). Each 50 ft
heated hose section holds approximately 1.25
gallons (4.7 liters) of fluid.
Connecting Additional Hose
Lengths
306
NOTE: For all steps below refer to the illustration on the
next page.
Up to six 50 ft (15.2 m) sections of heated hose can be
attached for a maximum total length of 300 ft (91.4 m).
36
1. Connect "A" and "B" material hoses using
necessary adapter fittings (supplied with heated
hoses).
2. Remove the elbow fittings at the end of the heated
hose assembly.
3. Connect the next length of hose, using union fittings
supplied with the hose.
NOTE: The tubes are color coded. Make sure all
colors match when connecting the fittings.
To prevent cross-contamination, ensure you
connect the "A" side fluid hose to the "A" side fluid
hose on the additional heated hose.
NOTICE