Fluid Control Assembly; Main Air Controls - Graco XP-H Series Operation, Repair, And Parts

Proportioners
Table of Contents

Advertisement

Component Identification

Fluid Control Assembly

Standard Mix Manifold shown
FH
FF
FE
FJ
FB
FN
F
. 3: Fluid Control Assembly
IG

Main Air Controls

For XP systems only.
F
. 4: Main Air Controls
IG
18
FA
FC
FM
FL
FK
FD
ti19167a
MG
Key:
FA Fluid Manifold
FB Mix Manifold
FC Circulation Handle (shown closed)
FD Solvent Flush Valve
FE Dual Shutoff Handle (shown closed)
FF Fluid Pressure Gauges
FG Fluid Supply Inlet (Behind Fluid Manifold)
FH Fluid Circulation Fittings
FJ B Component Adjustable Fluid Restrictor; see page 36
FK A and B Mix Manifold Check Valves
FL Solvent Inlet Check Valve
FM Automatic, Spring Loaded, Color-Coded Over Pressure
Relief Valves; with grease fittings; see page 52
FN A and B Combined Outlet; 3/8 npt(m)
Key:
MA Main Motor Shutoff Valve (Relieving)
MB Main Motor Air Pressure Regulator
MC Air Filter with Auto Drain
MD Main Motor Air Pressure Gauge
ME Filtered Air Distribution Manifold
MG Air Pressure Relief Valve
3A0420ZAF

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp seriesXp35Xp50Xp50-hXp70-hXp70

Table of Contents