Cylinder Charge Transfer Cut-In Temperature Limit; Cylinder Charge Transfer Cut-Out Temperature Limit - Buderus Logamatic SC40 Installation And Servicing Instructions

Solar thermal controller
Hide thumbs Also See for Logamatic SC40:
Table of Contents

Advertisement

Service level menu (for qualified heating engineers only)
7.5.14 Swimming pool maximum temperature
Menu: Service > Settings > Swimming pool maximum temperature
If configuration S6 is selected, the maximum temperature of the swimming pool can also be set.
When the maximum temperature is reached, the solar system pump is switched off.
Setting range
20 - 90 °C
Tab. 27
7.5.15 Cylinder charge transfer cut-in temperature differential
Menu: Service > Settings > Charge transfer cut-in temperature differential
In solar systems with preheating cylinder and standby cylinder, the cylinder contents are transferred
as soon as the temperature of the standby cylinder drops below that of the preheating cylinder. The
cut-in temperature differential is definable.
Setting range
7 - 20 K (°C)
Tab. 28
7.5.16 Cylinder charge transfer cut-out temperature differential
Menu: Service > Settings > Charge transfer cut-out temperature differential
If the temperature difference falls below the set figure, cylinder charge transfer is stopped.
Setting range
4 - 17 K (°C)
Tab. 29
Logamatic SC40 - Technical specifications are subject to change without prior notice.
Default setting
60 °C
Default setting
10 K (°C)
Default setting
5 K (°C)
7
New setting
New setting
New setting
61