Keithley touch, test, invent Series Declassification And Security Instructions

Keithley touch, test, invent Series Declassification And Security Instructions

Advertisement

Quick Links

Keithley Instruments
28775 Aurora Road
Cleveland, Ohio 44139
1-800-935-5595
tek.com/keithley
Introduction
If you have data security concerns, this document tells you how to clear or sanitize instrument memory devices
in the Keithley touch, test, invent
that is not functioning.
The procedures in this document are written to meet the requirements specified in:
NISPOM, DoD 5220.22-M, chapter 8
ISFO Process Manual for Certification and Accreditation of Classified Systems under NISPOM
Products
This document contains procedures for the following Keithley Instruments models:
2450, 2450-NFP, 2450-NFP-RACK, and 2450-RACK
2460, 2460-NFP, 2460-NFP-RACK, and 2460-RACK
2461, 2461-NFP, 2461-NFP-RACK, and 2461-RACK
2461-SYS
2470 and 2470-RACK
DMM7510, DMM7510-NFP, DMM7510-NFP-RACK, and DMM7510-RACK
Contact information
If you have any questions after you review the information in this documentation, please contact your local
Keithley Instruments office, sales partner, or distributor. You can also call the corporate headquarters of
Keithley Instruments (toll-free inside the U.S. and Canada only) at 1-800-935-5595, or from outside the U.S. at
+1-440-248-0400. For worldwide contact numbers, visit the
077086201 / July 2019
touch, test, invent Series Instruments
Declassification and Security Instructions
®
(TTI) series of instruments. It also explains how to declassify an instrument
*P077086201*
Keithley Instruments website
(tek.com/keithley).
1

Advertisement

loading

Summary of Contents for Keithley touch, test, invent Series

  • Page 1 If you have any questions after you review the information in this documentation, please contact your local Keithley Instruments office, sales partner, or distributor. You can also call the corporate headquarters of Keithley Instruments (toll-free inside the U.S. and Canada only) at 1-800-935-5595, or from outside the U.S. at +1-440-248-0400. For worldwide contact numbers, visit the Keithley Instruments website (tek.com/keithley).
  • Page 2: Description Of Memory

    Series Instruments Declassification and Security Instructions Terminology The following terms may be used in this document:  Clear: Removes data on media or in memory before reusing it in a secured area. Clears all reusable memory to deny access to previously unsecured information.
  • Page 3: Memory Devices

    Series Instruments Declassification and Security Instructions The BLASTER (U1 on the 2450-140 board) contains instrument logic, calibration data, and customer scripts, readings, and data:  Two 16 MB nonvolatile NOR FLASH chips on the Digital board ...
  • Page 4: Nonvolatile Memory Devices

    Series Instruments Declassification and Security Instructions Volatile memory devices The following table lists the volatile memory devices in the TTI products and memory-related information. Type and Function User Data input Location To clear To sanitize minimum size...
  • Page 5: Clearing Data

    Series Instruments Declassification and Security Instructions Clearing data You can use TSP scripts to clear data. You can run these scripts from the front panel using a flash drive or run them remotely. Clearing data scripts and setups To clear the data scripts and setups: 1.
  • Page 6: Lan Reset

    Series Instruments Declassification and Security Instructions LAN reset LAN RESET resets the LAN settings and the instrument password to the factory default values.To do this reset, insert a straightened paper clip into the hole labeled LAN RESET.

This manual is also suitable for:

24502450-nfp2450-nfp-rack24602450-rack2460-nfp ... Show all