Charging a Hot or Cold Battery Pack
A red and green flashing indicator light on the charger
indicates that the battery pack temperature is outside the
charging range. Once the pack is within the acceptable
range, normal charging will take place and the red light will
be continuous. Hot or cold battery packs may take longer to
charge.
Lithium-Ion Charging Status
Battery Pack
Red Charger
Temperature
Indicator Light
Too hot
Flashing
Normal range
Continuous
Too cold
Flashing
Operation
m
IMPORTANT!
This pressure washer is equipped with
a micro-switch sensitive to water flow. This Total Stop System
(TSS) senses water flow in the pump. When the trigger is
released, water stops flowing through the pump. The TSS then
automatically turns the motor off to protect the pump from
overheating, thus saving energy and prolonging pump life.
The TSS system will work only when there's water in the
bucket or the base unit is connected with a water supply.
When there's no water connected with the unit, the On/Off
button has to be pressed to stop the unit.
m
IMPORTANT!
This system is capable of producing
8 Mpa. To avoid rupture and injury, do not operate this pump
with components rated less than 8 Mpa working pressure
(including but not limited to spray guns, hose, and hose
connections).
1. Open the battery compartment cover and slide the battery
in until it clicks to lock it into position, then close the
battery compartment cover (Fig. 16).
Fig. 16
Battery
compartment
cover
2. Remove the water bucket from the base unit and fill with
clean (fresh) water (Fig. 17).
Fig. 17
Charging
Status
Not charging
Normal charging
m
Not charging
exceed 104ºF/40ºC.
m
(fresh) water; use of unfiltered water containing corrosive
chemicals will damage the washer.
m
fixed on the base unit.
3. Put the bucket back on the base unit. Make sure the
NOTE: If you do not want to use the bucket, you can use
the base unit directly as a pressure washer. See following
instructions (step 4 – 5) to learn how to connect the base unit
with a water supply.
4. Connect the garden hose adapter (female coupler) to
12
WARNING!
The intake water temperature must not
CAUTION!
The washer must only be used with clean
WARNING!
Do not fill the bucket with the bucket still
bucket is properly aligned on the base. Latch and lock
the buckles to ensure the bucket is securely connected
before using (Figs. 4 – 5).
the water inlet of the pressure washer on the base unit,
then thread your garden hose (male end) into the garden
hose adapter (Fig. 18). The garden hose must have an
internal diameter of at least 13 mm (1/2 in.) and must be
reinforced. The water supply must be at least equal to the
washer delivery capacity.

Advertisement