Atlas Copco GA 5 VSD MED Instruction Book page 69

Oil-injected rotary screw compressors
Table of Contents

Advertisement

Instruction book
-
Connect the condensate drain outlet(s) to a drain collector.
See section
-
For compressors with a DD or a DD and PD filter connect the automatic drain of the filters to a suitable
drain collector.
-
Check the oil level. The sight-glass (Gl) should be between 1/4 and 3/4 full. See section
change
-
Provide labels, warning the operator that:
The compressor may automatically restart after voltage failure (if activated, consult Atlas Copco).
The compressor is automatically controlled and may be restarted automatically.
-
Affix the above sheet, explaining the procedure for checking the motor rotation direction, to the cooling
air outlet of the compressor. Consult section
Switch on the voltage. Start the compressor and stop it immediately. Check the rotation direction of
drive motor (M1) while the motor is coasting to a stop.
Check the rotation direction of the motor. If the motor rotation direction is correct, the sheet on the top
grating will be blown upwards. If the sheet remains in place, the rotation direction is incorrect.
If the rotation direction of the drive motor is incorrect, open the isolating switch and reverse two incoming
electric lines.
Incorrect rotation direction of the drive motor may cause damage to the compressor.
-
Check the programmed settings. Consult section
-
Start and run the compressor for a few minutes. Check that the compressor operates normally.
2920 7104 10
Condensate
system.
for instructions.
Dimension
drawings.
Programmable
settings.
Oil and oil filter
67

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents