UMPETHA 082009/072010.014
Changing switch type for safety beam input:-
Default:- Normally open
Action
Response
1.
Program jumper on
2 beeps
2.
Dip-switch 1 and 2 on
Beeps confirm change
3.
Press and release Set button
1 beep = N/C
2 beeps = N/O (Default)
After confirmation beeps
Continuous beep
4.
Dip-switch 1 and 2 off
Continuous beep off
To change again without leav ing programming, repeat from point 2.
Remov e program jumper or continue to another programming option