Emerson CoreSense Technical Information page 8

Diagnostics for stream refrigeration compressors
Hide thumbs Also See for CoreSense:
Table of Contents

Advertisement

LED
flashes
Status LED description
count
Low Oil
1
Pressure
2
NA
Protection
Discharge
Discharge
3
Temp.
Current
4
Sensor
Fault
Communica
5
tion Error
6
NA
7
NA
8
N/A
Low Voltage
9
N/A
Imbalance
Table 4
Technical Information
reset
Low Oil
NA
Pressure
Motor
NA
2 min
Trip
Discharge
2 min
Temp.
Temp.
NA
NA
NA
NA
Locked
Locked
5 min
Rotor
Rotor
Missing
Missing
5 min
Phase
Phase
Low
5 min
Voltage
Voltage
Voltage
5 min
Imbalance
Auto
Lockout
condition
time
Without
If
sufficient oil
without sufficient oil pressure for 4 seconds.
N/A
pressure for 2
If
minutes
without sufficient oil pressure for 2 minutes.
If
off because motor temperature has
NA
exceeded set point. (3 series PTCs; 1 input)
(Trips at 4.5K Ohms, and will reset when
below 2.75K Ohms.)
If
temperature probe is open or disconnected.
If
has exceeded set point; compressor is
Exceeds max
turned off for 2 minutes before resetting.
set point
If
(configured in
exceeded set point and the compressor is
EEPROM from
locked out.
iPRO)
(The customer has configured the module
to lock out when the DLT temperature
exceeds the maximum set point.) DLT
probe is FACTORY INSTALLED
If
NA
NA
disconnected from the module. Compressor
run state is not known by module.
Communication between Control module
and iPro (/System) Controller has been lost.
Communication between Control module
NA
NA
and Sensor module has been lost.
Configuration miss-match between SW
configuration from iPro and HW (network
mode)
If
start, and excessive current may be present
in the compressor. The compressor is
10 consecutive
turned off and will remain off for 5 minutes.
events
If
and excessive current may be present in
the compressor. The compressor is locked
out after 10 consecutive events.
If
10 consecutive
off due to missing phase.
events
If
after 10 consecutive missing phase alarms.
If
10 consecutive
off due to low compressor voltage.
events
If
out after 10 consecutive low voltage alarms.
If
10 consecutive
off due to voltage imbalance.
events
If
out after 10 consecutive voltage imbalance.
Status LED troubleshooting information
flashing
green, compressor has been
flashing
red, compressor has been
flashing
orange, compressor is turned
flashing
green, the discharge
flashing
orange, discharge temperature
flashing
red, discharge temperature has
flashing
green, current sensor is
flashing
orange, compressor failed to
flashing
red, compressor failed to start,
flashing
orange, compressor is turned
flashing
red, the compressor is locked out
flashing
orange, compressor is turned
flashing
red, the compressor is locked
flashing
orange, compressor is turned
flashing
red, the compressor is locked