1.5.1.4
VCC current consumption in fixed active-mode (power saving disabled)
Power saving configuration is by default disabled, or it can be disabled using the appropriate AT command
u-blox AT Commands Manual
(refer to
module does not automatically enter idle-mode whenever possible: the module remains in active-mode.
The module processor core is activated during active-mode, and the 26 MHz reference clock frequency is
used.
Figure 9Figure 9
roughly describes the current consumption profile of SARA-G300 / SARA-G310 modules
when the EXT32K input pin is fed by external 32 kHz signal with characteristics compliant to the one
SARA-G3 series Data Sheet
specified in
when power saving is disabled. The module is registered with the network, active-mode is maintained, and
the receiver and the DSP are periodically activated to monitor the paging channel for paging block
reception.
Current [mA]
60-120 mA
100
50
3-5 mA
0
Paging period
Current [mA]
0.47-2.12 s
100
50
3-5 mA
0
Figure 9: VCC current consumption profile versus time of the SARA-G300 / SARA-G310 modules (with the EXT32K input pin fed by proper
external 32 kHz signal
or by
32K_OUT
the active-mode is always held, and the receiver and the DSP are periodically activated to monitor the paging channel
UBX-13000995 - R06
SARA-G3 series - System Integration Manual
[2], AT+UPSV command). When power saving is disabled, the
[1], or by the 32K_OUT output pin provided by these modules,
60-120 mA
20-40 mA
RX
DSP
Enabled
Enabled
ACTIVE MODE
output pin),
when registered with
Objective Specification
Time [s]
3-5 mA
Time [ms]
the network, with
power saving disabled:
System description
Page 34 of 218