Parameter
Description
number
10.11
Ext therm sensor - ID
11
External IO
11.01
1DI0 function
11.02
1DI1 function
11.03
1DI2 function
11.04
1DI3 function
11.05
1DI4 function
11.06
2DI5 function
11.07
2DI6 function
11.08
2DI7 function
11.09
1DO0 function
11.10
1DO1 function
11.11
2DO2 function
11.12
2DO3 function
11.13
1AO0 reference
11.14
1AO0 type
11.15
1AO0 max value
11.16
1AO0 min value
12
Communication
12.01
Com3 function
12.02
FB interface connector
12.03
Fieldbus control
12.04
Fieldbus address
12.05
Fieldbus IP address
12.06
Fieldbus IP gateway
12.07
Fieldbus IP netmask
12.08
Fieldbus IP DHCP client
Setting range
No sensor, PTC element, 3-wire PT100,
2-wire PT100, Bi-metal switch
None, Reset, Enable, Slow speed forward,
Slow speed reverse, Motor heating, Stand-
still brake, Start reverse, User defined
protection, Emergency mode, Fieldbus
disable control, Start 1, Start 2, Start 3 ***
0 ... 15 ***
0 ... 15 ***
None, Reset, Enable, Slow speed forward,
Slow speed reverse, Motor heating, Stand-
still brake, Start reverse, User defined
protection, Emergency mode, Fieldbus
disable control, Start 1, Start 2, Start 3 ***
0 ... 15 ***
0 ... 15 ***
0 ... 15 ***
0 ... 15 ***
None, Run, Top of ramp, Event group 0,
Event group 1, Event group 2, Event group
3, Event group 4, Event group 5, Event
group 6, Sequence 1 Run, Sequence 2 Run,
Sequence 3 Run, Sequence 1 TOR,
Sequence 2 TOR, Sequence 3 TOR *** *
0 ... 15 *** *
0 ... 15 *** *
0 ... 15 *** *
0-10 mA, 0-20 mA, 4-20 mA, 0-10 V
Motor current [A], Mains voltage [V], Active
power [kW], Active power [HP], Reactive
power [kVAr], Apparent power [kVA], Active
energy [kWh], Reactive energy [kVArh],
COS [ ], Motor temperature [%], Thyristor
temperature [%], Motor voltage [%]
Mains frequency [Hz], PT100 temperature
[centigrade], PTC resistance [Ω]
0 ... 1000000
0 ... 1000000
None, Test, Modbus RTU slave. Extension
I/O
FbPlug, Modbus RTU, Anybus, None
On / Off
0 ... 65535
000.000.000.000
000.000.000.000
255.255.255.000
On / Off
1SFC132081M0201
Number of
Fieldbus
decimals
ID
0
226
0
145
0
146
0
147
0
148
0
149
0
150
0
151
0
152
0
153
0
154
0
155
0
156
0
157
0
158
0
159
0
160
0
26
0
32
0
45
0
51
0
58
0
59
0
83
0
92
| Installation and commissioning manual | Functions
Default value
Actual
setting
No sensor
None
None
None
None
None
None
None
None
None
7
None
None
None
4-20 mA
Motor current
[A]
500
0
Test
None
Off
0
0
0
255.255.255.0
Off
135