COMPONENT TESTING
Voltage Table
FROM
TO
VOLTAGE
P1
P1-1
P1-2
CONSTANT 115 VAC
P2-5
P1-2
RC DEFROST HEATER OUTPUT, WITH THERMAL FUSE 115V
P2
P2-6
P1-2
ICE MAKER DUCT CABINET HEATER
P2-7
P1-2
FC DEFROST HEATER OUTPUT, WITH THERMAL FUSE 115V
P3
P3-1
P1-1
115 VAC
FC ICE MAKER FILL TUBE HEATER
P3-2
P1-1
FC DOOR RV MUST BE CLOSED = 115 V, OPEN = 0 V
P3-3
P1-2
DOOR ICE MAKER WATER VALVE
P3-4
P1-2
ISOLATION VALVE
P3-5
P1-2
CONSTANT 115 VAC, AC LINE INTERLOCK
P3-7
P3-8
130 VDC
AUGER OUTPUT, LH RH DOOR CLOSED, ACTIVATE ICE PADDLE = 130-140 VDC
P3-6
P1-2
115 VAC
FC ICE MAKER WATER VALVE
P4-1
P4-4
12.7 VDC
CONSTANT 12.7 VDC
P4
P4-3
COMMUNICATION
WIN DATA
P5-1
P5-2
5 VDC
FC THERMISTOR OUTPUT = 1.5-5 VDC MAXIMUM
P5
P5-3
P5-4
5 VDC
RC THERMISTOR OUTPUT = 1.5-5 VDC MAXIMUM
P6
P6-1
P6-2
12.7 VDC
CONSTANT 12.7 VDC
P7-1
P7-2
5 VDC
FC ICE MAKER THERMISTOR OUTPUT = 1.5 - 5 VDC. MAXIMUM
P7
P7-3
P7-4
5 VDC
FC ICE MAKER SWITCH VOLTAGE = 12.7 VDC, WHEN OPEN
P7-5
P7-6
12.7 VDC
FC ICEMAKER MOTOR
P8-1
P8-2
5 VDC
RC EVAP THERMISTOR OUTPUT = 1.5 - 5 VDC. MAXIMUM
P8
P8-3
P8-4
5 VDC
FC EVAP OUT THERMISTOR OUTPUT = 1.5 - 5 VDC. MAXIMUM
P8-7
P8-8
12.7 VDC
DC CONDENSER FAN OUTPUT
P9
P9-2
P9-3
12.7 VDC
ICE BOX FAN OUTPUT
P12-1
P1-2
AIR BAFFLE FEEDBACK. ACTIVATE SERVICE TEST 42
P12
115 VAC
P12-6
P1-2
AIR BAFFLE OUTPUT. ACTIVATE SERVICE TEST 42
P13
P13-5
P8-4
5 VDC
PANTRY THERMISTOR OUTPUT = 1.5 - 5 VDC. MAXIMUM
P14-1
P14-2
12.7 VDC
FC EVAP FAN OUTPUT
P14
P14-3
P14-4
12.7 VDC
RC EVAP FAN OUTPUT
P1-1
P1-2
P1
115 VAC
CONSTANT 115 VAC
P1-3
P1-4
P2
P2-4
P1-2
FILTER HEATER
P3
P3-2
P1-2
BEVERAGE CHILLER DUCT HEATER
P4-1
P4-4
12.7 VDC
CONSTANT 12.7 VDC
P4
P4-3
COMMUNICATION
WIN DATA
P5
P5-1
P5-2
5 VDC
FC EVAP IN THERMISTOR OUTPUT = 1.5 - 5 VDC. MAXIMUM
P7-1
P7-4
RC RIGHT DOOR, SWITCH VOLTAGE = 12.7 VDC, WHEN OPEN
P7
P7-3
P7-4
RC LEFT DOOR, SWITCH VOLTAGE = 12.7 VDC, WHEN OPEN
P8-1
P8-2
12.7 VDC
12.4 VDC
P8
P8-3
P8-4
12.7 VDC
LED OUT 12.7 VDC WHEN TURNED ON
P8-5
P8-6
12.7 VDC
LED OUT 12.7 VDC WHEN TURNED ON
P9-1
12.7 VDC
CONSTANT 12.7 VDC
P9
P9-2
P9-3
12.7 VDC
PULSED 12.7 VDC
P9-4
P9-5
12.7 VDC
PULSED 12.7 VDC
P10
P10-1
P10-2
12.7 VDC
FLANGE HEATER/ WINDOW HEATER = 0 - 12.7 VDC (MAXIMUM)
P15-1
VARIABLE FREQUENCY AND AMPLITUDE 115 VAC
P15
P15-2
VARIABLE FREQUENCY AND AMPLITUDE 115 VAC
P15-3
VARIABLE FREQUENCY AND AMPLITUDE 115 VAC
n
French-Door Bottom Mount Refrigerator
2-4
For Service Technician Use Only
CONDITIONS
FROM
TO
VOLTAGE
P16-1
P16-8
P16-2
P16-7
P16
12.7 VDC
CONSTANT 12.7 VDC
P16-3
P16-6
P16-4
P16-5
J2-2
COMMUNICATION
WIN DATA
J2
J2-4
J2-1
12.7 VDC
CONSTANT 12.7 VDC
J3
J3-2
J3-1
5 V
PROXIMITY SENSOR
J6
J6-1
J6-2
12.7 VDC
FLIPPER MULLION HEATER OUTPUT (LEFT DOOR)
J4-1
J4-4
12.7 VDC
CONSTANT 12.7 VDC
J4
J4-3
COMMUNICATION
WIN DATA
J5-1
CONSTANT 12.7 VDC
J5-2
PULSED 12.7 VDC
J5
J5-3
PULSED 12.7 VDC
J5-4
PULSED 12.7 VDC
J5-5
PULSED 12.7 VDC
J6-1
J6-3
12.7 VDC
SWITCH VOLTAGE = 12.7 VDC, WHEN OPEN
J6
J6-4
J6-6
12.7 VDC
SWITCH VOLTAGE = 12.7 VDC, WHEN OPEN
J8-1
J8-2
DISPENSER HEATER, PULSED = 0 - 12.7 VDC (MAXIMUM)
J8-3
J8-4
FILL TUBE HEATER, PULSED = 0 - 12.7 VDC (MAXIMUM)
J8
J8-5
J8-6
WATER VALVE, PULSED = 0 - 12.7 VDC (MAXIMUM)
J8-7
J8-8
DOOR DUCT HEATER, PULSED = 0 - 12.7 VDC (MAXIMUM)
J10-1
J10-2
3.3 VDC
ICE BOX THERMISTOR OUTPUT = 0 - 3.3 VDC. MAXIMUM
J10-3
J10-4
3.3 VDC
DOOR ICE MAKER THERMISTOR OUTPUT = 0 - 3.3 VDC. MAXIMUM
J10
J10-5
J10-6
3.3 VDC
SWITCH VOLTAGE = 3.3 VDC, WHEN OPEN
J10-7
J10-8
3.3 VDC
SWITCH VOLTAGE = 3.3 VDC, WHEN OPEN
J10-9
J10-10
12.7 VDC
ICE MAKER MOTOR
J1-1
J1-4
12.7 VDC
CONSTANT 12.7 VDC
J1
J1-3
COMMUNICATION
WIN DATA
CONDITIONS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents