Adam Pumps PA1 70A Use And Maintenance Manual

Adam Pumps PA1 70A Use And Maintenance Manual

Diesel fuel pump

Advertisement

ENGLISH (TRANSLATION OF ORIGINAL INSTRUCTIONS)
USE AND MAINTENANCE MANUAL
Machine:
Models:
the use and maintenance manual must be carefully stored near the machine in an environment protected against
. t
humidity and heat
he manual must accompany the machine if sold
.
part of the manual
We, ADAM PUMPS S.p.A., with our registered office in Via della Resistenza, 46/48, 41011, Campogalliano (MO), ITALY; represented
by Davide Stassi, authorised to compile the relevant technical file at the undersigned premises,
Used as a diesel fuel pump to be integrated into a system for transferring fuel from a gravity tank.
Technical specifications
Directive 2006/42/EC of the European Parliament and of the Council of 17 May 2006 on machinery, and amending Directive 95/16/
EC.
Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the
Member States relating to electromagnetic compatibility.
Directive 2014/35/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the
Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits.
Directive 2014/68/EU of the European Parliament and of the Council of 15 May 2014 on the harmonisation of the laws of the
Member States relating to the making available on the market of pressure equipment.
Place and date of the document
Campogalliano, 1st October 2015
Adam Pumps spa
Via della Resistenza 46/48 - 41011 Campogalliano (MO) ITALY
Tel +39 059 528128 - Fax +39 059 528437
www.adampumps.com - info@adampumps.com
DIESEL FUEL PUMP
PA1 70A, PA2 80, PA2 100, PA3 150
EC DECLARATION OF CONFORMITY
(Annex II A DIR. 2006/42/EC)
THE MANUFACTURER
DECLARES THAT THE MACHINE
Batch of
Model
Code : PA7A00
Description
PUMP PA1 70 - 230V
230 Volt - 50 Hz - IP 55 - 550W - 2,5 A
2800 rpm - Condensator: 450 v-16 µF
Weight
Weight Kg.: 8
COMPLIES WITH DIRECTIVES
. i
t is prohibited to damage
The legal representative
UM033
11/2017 - rev. 06
EN
,
modify or remove any

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PA1 70A and is the answer not in the manual?

Questions and answers

Summary of Contents for Adam Pumps PA1 70A

  • Page 1 (Annex II A DIR. 2006/42/EC) THE MANUFACTURER We, ADAM PUMPS S.p.A., with our registered office in Via della Resistenza, 46/48, 41011, Campogalliano (MO), ITALY; represented by Davide Stassi, authorised to compile the relevant technical file at the undersigned premises, DECLARES THAT THE MACHINE Used as a diesel fuel pump to be integrated into a system for transferring fuel from a gravity tank.
  • Page 2: Table Of Contents

    Reproduction rights: This manual is the property of ADAM PUMPS S.p.A., which is the sole owner of all rights provided for by applicable law, including without limitation copyright rules. All rights under these rules belong to ADAM PUMPS S.p.A.: reproduction, even partial, of this manual, its publication, modification, transcription, public...
  • Page 3: Technical Specifications

    POWER WORK FLOW OUTPUT NOISE CURRENT [WATT] CYCLE RATE [BSP-G]: [DBA] [AMP] [MIN] [L/MIN]: PA1 70A AC 230V / 552W (S1) > 70 1" - 1" < 70 230V/50Hz 50Hz Continuous PA1 70A AC 230V / 667W (S1) > 70 1"...
  • Page 4: Power Supply

    ENGLISH (TRANSLATION OF ORIGINAL INSTRUCTIONS) 3.2 - p ower supply Depending on the model, the pump must be powered by the single-phase or three-phase AC line whose values are given in the table in section 2.3 - Technical specifications. Powering the pump with values outside these limits can damage the electrical components or cause them to malfunction.
  • Page 5: Hydraulic Pipe Connection

    CAUTION! Do not use couplings or connection fittings with conical threading, as these could damage the pump coupling outlets if tightened too much. We recommend using ADAM PUMPS suction and discharge pipes, which are designed specifically for the pump in use; alternatively, respect the dimensions and specifications in the table below.
  • Page 6: Electrical Connection Of The Pump

    ENGLISH (TRANSLATION OF ORIGINAL INSTRUCTIONS) 5.4 - e lectrIcal connectIon of the pump SINGLE-PHASE MOTORS Pumps with single-phase motors are supplied with a 2 m cable and plug. To change the power cable, open the capacitor box cover and follow the connection diagram to the side.
  • Page 7: Noise Level

    ENGLISH (TRANSLATION OF ORIGINAL INSTRUCTIONS) conditions for the pump can cause the motor temperature to rise and its subsequent shutdown by the circuit breaker. Switch the pump off and wait for it to cool down before resuming work. The circuit breaker automatically switches off when the motor has cooled sufficiently. CAUTION! During the first priming phase, the pump must be able to discharge the air, initially present in the suction pipe and in the pump, from the discharge line.
  • Page 8: Troubleshooting

    ENGLISH (TRANSLATION OF ORIGINAL INSTRUCTIONS) 7 - TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION THE PUMP DOES Power failure Check the electrical connections and the safety devices NOT START UP The circuit breaker has tripped Use the electric pump in the recommended operating conditions and according to its intended use (chap.
  • Page 9: Demolition And Disposal

    ENGLISH (TRANSLATION OF ORIGINAL INSTRUCTIONS) The machine is designed to minimise routine maintenance. It is the operator’s responsibility to assess the status and its suitability for use. We recommend stopping the operations and performing maintenance every time operation is not perfect. This will always allow maximum efficiency. Always use the appropriate PPE (Personal Protective Equipment): CAUTION! Make sure the pump is disconnected from the power supply and is not in operation before carrying out any maintenance.
  • Page 10: Warranty

    - the warranty will not be valid in the event the product is tampered with by unauthorised persons, bodies, and/or companies; - any warranty request is subject to approval by Adam Pumps. The goods can be returned only if provided with an authorisation code. Upon request, Adam Pumps will provide this code which will invoke the warranty for the product to be repaired or replaced unless otherwise agreed with Adam Pumps, the returned goods must be sent via transport pre-paid by who has invoked the warranty to Adam Pumps Spa;...
  • Page 11 PA023 capacitor box Proprietà della ADAM PUMPS Spa - Senza autorizzazione scritta della stessa il presente disegno non potrà essere comunq costruzione dell' oggetto rappresentato, nè venire comunicato a terzi o riprodotto. La società proprietaria tutela i propri dirit PA019...
  • Page 12 ENGLISH (TRANSLATION OF ORIGINAL INSTRUCTIONS) PA2 80 POS. DESCRIPTION CODE POS. DESCRIPTION CODE black power cable 190200000000 wound stator mec 71 64100000000 bypass valve 71000520 gasket fv 63/71-2 10501000000 pump body 80l 1” bsp/g 71000060 capacitor holder 140250100000 bypass spring 16001005 vt004 self-t.
  • Page 13 ENGLISH (TRANSLATION OF ORIGINAL INSTRUCTIONS) PA2 100 POS. DESCRIPTION CODE motor 230v mec 80 71009018 black power cable 190200000000 bypass valve 71000520 bypass spring 16001005 plate 71000521 large stainless steel filter 41410000 or 3118 nbr 18001008 cap 1” 17001094 "filter" plate 71000587 "filter cleaning"...
  • Page 14 ENGLISH (TRANSLATION OF ORIGINAL INSTRUCTIONS) PA3 150 NOTE PA3 150L: do not do under 5-second motor restarts POS. DESCRIPTION CODE hex socket head cap screw M5X16 ISO 4762 13001007 pump cover 80-100 L. 71000063 large vane 71000569 impeller ø72 61000010 O-Ring 85X3 NBR 18001022 thread protection cap ø31...
  • Page 15: Wiring Diagrams

    ENGLISH (TRANSLATION OF ORIGINAL INSTRUCTIONS) 12.2 w IrIng dIagrams PA1 70 - PA2 80 - PA2 100 ON-OFF switch Motor Circuit Breaker Capacitor A.C. S1 : Interruttore ON - OFF PA3 150 M : Motore ON-OFF switch Motor T : Protezione Termica Circuit Breaker C1 Phase capacitor C : Condensatore...
  • Page 16: Overall Dimensions And Weights

    A 7000 Proprietà della ADAM PUMPS Spa - Senza autorizzazione scritta della stessa il presente disegno non potrà essere comunque utilizzato per la costruzione dell' oggetto rappresentato, nè venire comunicato a terzi o riprodotto. La società proprietaria tutela i propri diritti a rigore di legge.

This manual is also suitable for:

Pa2 80Pa2 100Pa3 150Pa7050Pa6050Pa 8050