Desktop Mounting; 19-Inch Rack Mounting - Denwa Communications DW-GTW-AC-E1060 Quick Installation Manual

Digital voip gateways
Table of Contents

Advertisement

4.1

Desktop Mounting

The device can be placed on a desktop when its four anti-slide bumpers (supplied)
are attached to the underside of the device.
To attach the anti-slide rubber bumpers to the device:
1.
Flip the device over so that its underside faces up.
2.
Locate the four anti-slide grooves on the underside - one in each
corner.
3.
Peel off the adhesive, anti-slide rubber feet and stick one in each anti-
slide groove.
Figure 4-1: Rubber Foot Attached to Underside of Device
4.
Flip the device over again so that it rests on the rubber feet and place
it in the required position on a desktop.
4.2

19-Inch Rack Mounting

The device can be installed in a standard 19-inch rack by implementing one of the
following mounting methods:
● Placing it on a pre-installed shelf in a 19-inch rack
● Attaching it directly to the rack's frame using the device's mounting brackets
(supplied) that need to be attached to the chassis
When installing the chassis in a rack, implement the following safety
instructions:
·
Elevated Operating Ambient Temperature: If installed in a
closed or multi-unit rack assembly, the operating ambient temperature
of the rack environment may be greater than room ambient temperature.
Therefore, consideration should be given to installing the equipment in
an environment with maximum ambient temperature (Tma) of 40°C
(104°F).
·
Reduced Air Flow: Installation of the equipment in a rack should
be such that the amount of air flow required for safe operation on the
equipment is not compromised.
·
Mechanical Loading: Mounting of the equipment in the rack
Rack Mount Safety Instructions