Scanning the Picture of the
Alarm Recordings — Alarm Scan
1
1
Turn on the power of the equipment to be used.
2
Press SEARCH twice in stop mode.
The AL SCAN lights in the display window or on
the monitor screen.
H
M
S
In the display window
3
Press ) FF or 0 REW.
The portions where the alarm function worked are
subsequently played back for five seconds one by
one.
Press P PAUSE to view a certain scene in still mode.
(Alarm scan mode is released.)
Press p STOP, z PLAY, ) FF, or 0 REW to
release alarm scan mode.
Note
If the tape reaches the end during scanning, the tape is
rewound and the unit enters the stop mode at the
beginning of the tape.
3
2
1 H 1 2 M 0 6 S
A L S C A N
On the monitor screen
Displaying the Alarm List —
Alarm Recall
1
MENU RESET
1
Turn on the power of the equipment to be used.
2
Press MENU until the ALARM TIME display
appears on the screen.
The alarm count, date and time are displayed.
The date and time are displayed up to recent eight
times.
<
ALARM T I ME
008
0 3 - 1 2
1 9 – 0 0
0 1 - 1 1
2 3 – 0 0
2 5 - 1 0
1 5 – 0 0
2 5 - 1 0
0 8 – 0 0
2 5 - 1 0
0 6 – 0 0
1 5 - 1 0
2 0 – 0 0
1 5 - 1 0
1 6 – 3 5
1 5 - 1 0
1 0 – 5 2
To turn off the alarm list on the screen
Press SEARCH. The normal display appears.
To reset the alarm data
Press MENU RESET while the ALARM TIME
display is on the screen.
The alarm count shows "000".
SEARCH