Undersink reverse osmosis drinking water system (29 pages)
Summary of Contents for EcoWater ETF AIIF10
Page 1
OWNER’S MANUAL How to maintain and operate your EcoWater birm filter with air injected assembly and turbine initiated flow switch MODEL ETF AIIF10 EcoWater Systems P .O. Box 64420 St.Paul MN 55164 - 9888 (651) 739---5330 PRINTED IN U.S.A. Part No. 7322827 (Rev. D 5/15/12)
ECOWATER Unpacking, Table of Contents Y S T UNPACKING TABLE OF CONTENTS EcoWater Air Injected Iron Filters are shipped from PAGE the factory with the following: Safety Guides Specifications / Dimensions -- Filter assembly, packed with quartz and birm z...
ECOWATER Safety Guides Y S T SAFETY GUIDES Recommended maximum allowable inlet water pressure is 80 psi. Use a pressure reducing valve if Follow the installation instructions carefully. Failure to necessary. Be sure the addition of a pressure reducing install the filter properly voids the warranty.
ECOWATER Specifications / Dimensions Y S T BIRM FILTER WITH AIR INJECTION ASSEMBLY Filter Type ....Oxidizing Minimum Water Supply pH ..7.0 Type of Mineral .
ECOWATER Typical Finished Installation Y S T TYPICAL FINISHED INSTALLATION FIGURE 1 FILTERED WATER CROSS - - OVER Use if water supply flows from the left. Include single or 3 - - valve bypass. 120 Volt WATER IN Outlet UNFILTERED...
(check your codes). For compression adaptors. The following special fittings a rigid valve drain run, plumb according to local are available from EcoWater. Be sure to comply codes. To connect to the valve drain fitting, pur- with all local plumbing codes.
ECOWATER Installation Y S T FIGURE 3 OUTSIDE FAUCETS COLD Chemical Pressure Feed System tank Water Taste & Water Air Injected Water Sediment Blending Heater Odor Softener Iron Filter Neutralizer Filter Tank Filter Filter Well Pump 1. INSTALL SINGLE BYPASS VALVE and/or...
Page 8
ECOWATER Installation Y S T 2. TURN OFF WATER SUPPLY ground continuity. If you use the plastic bypass valve at the filter, continuity is broken. To restore the a. Close the main water supply valve, near well ground, install one of the following grounds.
Page 9
ECOWATER Installation Y S T 8. INSTALL VALVE DRAIN HOSE b. Referring to Figure 7, turn the bypass valves to service position. a. Connect a length of 5/8” I.D. (minimum) hose to c. Slowly open the main water supply valve.
ECOWATER Installation Y S T FIGURE 8 BACK OF TIMER 24VAC 24VAC MOTOR TO 120V OUTLET TRANSFORMER POSITION SWITCH 1 POSITION CONNECT SWITCH 2 TO AIR PUMP TURBINE SENSOR TO 120V OUTLET SOLENOID RELAY BOX...
ECOWATER Programming Face Plate Timer Y S T FIGURE 9 UP keypad DOWN keypad display VACATION NOW (HOLD) RECHARGE keypad SELECT keypad I. When the transformer is plugged in, the model for fast advance. This procedure applies for all fol- code HAIIF shows in the face plate display for the lowing settings.
Page 12
ECOWATER Programming Face Plate Timer Y S T Iron (parts per million) Number of People 1 -- 2 3 -- 4 5 -- 7 8 -- 10 4 days 3 days 2 days 1 day 4 days 3 days 2 days...
ECOWATER Start Up Checklist Y S T After completing the preceding installation and programming steps, check all the following: Make sure the bypass valve(s) are in the “service” position. Check for leaks. Open a filtered water faucet and confirm that the air pump runs. Pump will run for 8 seconds after water flow has stopped.
ECOWATER Features / Options Y S T RECHARGE NOW -- For an immediate extra back- ADJUSTABLE BACKWASH -- Press and hold the SELECT button until the display shows “000----”, wash at any time, use this feature. Press and hold then press the SELECT button once to advance to in the RECHARGE keypad for three seconds until the Backwash time adjust screen.
ECOWATER Filter Operation Y S T GENERAL INFORMATION cleaning is done in two stages, or cycles, called backwash and fast rinse. It is started automatically The air injector adaptor installs between the filter by the timer. valve and mineral tank. A pump injects air into the BACKWASH (Figure 12): The timer starts the valve iron filter through the adaptor.
Page 16
ECOWATER Filter Operation Y S T FIGURE 12 BACKWASH CYCLE FLOW PLUG FIGURE 13 FAST RINSE CYCLE...
ECOWATER Service Information Y S T Description of Operation - - Air pump activation & solenoid venting system When service water flows through the filter, it rotates the turbine (located in the valve’s outlet port), sending a signal to the controller (PWA). The controller then activates a 24V power supply to the vent solenoid and relay box.
Page 18
ECOWATER Service Information Y S T MANUAL INITIATED ...Press the UP keypad to display the number of days this face plate has had electrical power ap- ELECTRONICS DIAGNOSTIC plied. 1. To enter diagnostics, press and hold the SELECT keypad until (000-- --) shows in the display.
Page 19
ECOWATER Service Information Y S T MANUAL ADVANCE DIAGNOSTICS NOTE: Be sure household water pressure (well sys- tem) is maintained at a minimum of 20 psi. Adjust the Use the following procedures to advance the filter pump switch upward, if needed.
ECOWATER Repair Parts Y S T Valve Assembly (see pages 22 & 23) WARNING: FILTER TANK CONTAINS AIR. TO RELIEVE PRES- SURE, PUT BYPASS VALVE IN BYPASS AND ADVANCE FILTER VALVE TO BACKWASH BEFORE DISASSEMBLY.
Page 21
ECOWATER Repair Parts Y S T PART PART DESCRIPTION DESCRIPTION 7085297 Transformer, 24V --- 40VA Distributor O---ring Kit 7112963 (includes Key Nos. 16---18) 7132840 Power Cord O---ring, 13/16 I.D. x 1---1/16 O.D. 7322801 Wire Harness, Solenoid O---ring, 2---7/8 I.D. x 3---1/4 O.D.
Page 22
ECOWATER Repair Parts Y S T flow plug assembly assembled view wear--- strip seal cross--- section view...
Page 23
ECOWATER Repair Parts Y S T PART PART DESCRIPTION DESCRIPTION 7224087 Screw, #6-20 x 7/8 (2 req.) 7077642 Copper Tube, 1” (2 req.) 7286039 Motor (incl. 2 ea. of Key No. 50) 7311127 O---ring, 1---1/16 x 1---5/16 (4 req.) 0900857 Screw, #6-20 x 3/8 (3 req.)
EcoWater Systems LLC, is excused if failure to perform its warranty obligations is the result of strikes, government regulation, materi- als shortages, or other circumstances beyond its control.
Need help?
Do you have a question about the ETF AIIF10 and is the answer not in the manual?
Questions and answers