Concerning SCOTT AV-3000
Facepieces
DATE: January 8, 2008
®
TO: All Users of SCOTT AV-3000
Facepieces
SOME USERS OF AV-3000 FACEPIECES HAVE REPORTED SEPARATION OF THE HEAD HARNESS
FROM THE FACEPIECE AT THE RUBBER ATTACHMENT TAB. SEPARATION OF THE TAB MAY
RESULT IN EXPOSING THE USER TO THE ATMOSPHERE THE RESPIRATOR WAS INTENDED TO
PROTECT THE USER AGAINST.
Carefully review this entire notice before taking action.
SCOTT has learned that some AV-3000 facepieces have separated at the rubber tab which connects
the head harness to the facepiece seal and lens.
FIGURE 1

AV-3000 Facepiece

Based on laboratory testing, the force needed to damage the faceseal is well beyond what is needed
to properly don a facepiece and achieve a good face-to-facepiece seal. As a result, most users have
not experienced damage to their equipment.
To achieve a good face-to-facepiece seal, the AV-3000
facepiece requires less tension on the head harness straps than some of the other SCOTT Facepiece
Models. This may lead some users to over tighten the straps on the AV-3000 facepiece.
Because reducing the potential of any risk begins with basic procedures, SCOTT is reminding users to
follow the steps in the Operation and Maintenance instructions regarding donning the facepiece. Prior
to donning your facepiece, inspect your respirator as discussed in your organized respiratory protection
program or as discussed in the Operations and Maintenance instructions originally supplied with your
respirator. Additional copies of the Operations and Maintenance instructions are available from SCOTT
upon request.
Page 1 of 4
H/S 6678

Advertisement

loading

Summary of Contents for Scott AV-3000

  • Page 1 RESULT IN EXPOSING THE USER TO THE ATMOSPHERE THE RESPIRATOR WAS INTENDED TO PROTECT THE USER AGAINST. Carefully review this entire notice before taking action. SCOTT has learned that some AV-3000 facepieces have separated at the rubber tab which connects the head harness to the facepiece seal and lens. FIGURE 1...
  • Page 2 DONNING THE AV-3000 FACEPIECE To begin use of respirator, don the facepiece (i.e., place facepiece on face and obtain a proper seal) as follows: 1. Examine the facepiece assembly to be certain the nose cup inhalation valves are installed, the nose cup is correctly positioned inside the face seal chin cup, and nose cup is properly seated between the flanges of the voicemitter ducts.
  • Page 3 3000 facepiece requires less tension on the head harness straps than some of the other SCOTT Facepiece Models. This may lead some users to over tighten the straps on the AV-3000 facepiece. you have any questions regarding donning a facepiece to achieve a good facepiece seal, contact the administrator of your organized respiratory protection program.
  • Page 4 Health & Safety Products Monroe Corporate Center PO Box 569 Monroe, NC 28111 Telephone 1-800-247-7257 FAX (704) 291-8330 www.scotthealthsafety.com Copyright © 2008, SCOTT, All Rights Reserved Page 4 of 4 H/S 6678...