3.4.3. RS-485 port Specifications and Wiring
The following table shows the pin names, functions, and data direction of the RS-485
communication port.
[RS-485 Port Specification of ETOS-XP Series]
Pin No.
Name
1-3, 6-8
TRX+
2-4, 7-9
TRX-
The following figure shows the RS-485 connection method between ETOS-XP and external device.
(TXD+)
(TXD-)
(RXD+)
(RXD-)
(TXD+)
(TXD-)
(RXD+)
(RXD-)
Signal Direction
↔
RS-485 Transmit/Receive Data(+)
↔
RS-485 Transmit/Receive Data(-)
[ RS-485 Connection Diagram ]
- 30 -
Function Description
ETOS-XP
1 (TXD+)
2 (TXD-)
3 (RXD+)
4 (RXD-)
5 (SG1)
6 (TXD+)
7 (TXD-)
8 (RXD+)
9 (RXD-)
10 (SG2)