Power:low:current - National Instruments RMX-400 Series Programming Manual

Programmable dc electronic load
Table of Contents

Advertisement

Example
Query Syntax
Return Parameter <NR2> [MAX|MIN]
Query Example

:POWer:LOW:CURRent

164B
Description
Syntax
Parameter
Example
RMX-4000 Series Programming Manual
AVALue MAX
:POWer:LOW:AVAL 1
:POWer:LOW:AVALue/BVALue? [MAX|MIN]
1 unit = 1 W
MAX/MIN
:POWer:LOW:BVAL? MAX
2
Sets the current limit for constant power mode for
the low range only.
:POWer:LOW:CURRent <NRf+>[A]
<NRf+>[A]
1
1A
MIN
MAX
:POW:CURR 1
Sets A Value to the
maximum level for the
specific channel
Sets A Value to 1 W for
the low range.
Current
Returns the power of the A
or B Value
Returns the allowable
maximum and minimum
Returns the maximum
power allowed for the
channel/range.
Channel-Specific
Command
Sets the current limit to
1 A.
Sets the current limit to
1 A.
Sets the current limit to
the minimum level for the
specific channel
Sets the current limit to
the maximum level for the
specific channel
Sets the current limit to
1 A.